Nightcap: A Reliable System for Determining Sleep Onset Latency
Open accessThe DOI matches its Crossref record.
Abstract
Previous studies have demonstrated that the Nightcap home-based sleep-monitoring system can differentiate waking, NREM and REM sleep based on eyelid movements (ELMs) and head movement behavior. The present study aims at determining the reliability of the Nightcap in determining the human sleep onset latency (SOL) as revealed by standard polysomnography (PSG). Four naps were recorded in each of ten normal subjects using both PSG and the Nightcap simultaneously. The Nightcap algorithm scored sleep onset as the first of 4 consecutive 30-sec epochs with less than 5 ELMs. The mean percentage of agreement between the Nightcap and PSG was 93% (k = 0.79), and the average absolute difference was 45 sec (13.3% of SOL(PSG)). SOL(NC) differed by less than 1 min in 85% of onsets. Recordings of EEG activity from 90 sec before and after PSG-identified sleep onsets were subjected to spectral analysis. Changes in spectral power in the theta (4-7 Hz) and alpha (8-12 Hz) frequency bands during the transition into light sleep correlated well with eyelid behavior. However, changes in ELM density predicted sleep onset better than did changes in theta and alpha spectral power. These results suggest that the Nightcap may be a potential alternative to the PSG technique in the assessment of SOL in normal subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The cognitive neuroscience of sleep: neuronal systems, consciousness and learning
Hobson, J. A., & Pace-Schott, E. F. (2002) · Nature Reviews Neuroscience · doi:10.1038/nrn915 · Cited by 835
Self-citationThe restorative effect of naps on perceptual deterioration
Mednick, S. C., Nakayama, K., Cantero, J. L., Atienza, M., Levin, A. A., Pathak, N., & Stickgold, R. (2002) · Nature Neuroscience · doi:10.1038/nn864 · Cited by 360
Self-citationSocial relationships, sleep quality, and interleukin-6 in aging women
Friedman, E. M., Hayney, M. S., Love, G. D., Urry, H. L., Rosenkranz, M. A., Davidson, R. J., Singer, B. H., & Ryff, C. D. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0509281102 · Cited by 247
Chan, A. S., Han, Y. M. Y., & Cheung, M.-C. (2008) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-008-9050-5 · Cited by 76
van Rijn, E., Eichenlaub, J.-B., Lewis, P. A., Walker, M. P., Gaskell, M. G., Malinowski, J. E., & Blagrove, M. (2015) · Neurobiology of Learning and Memory · doi:10.1016/j.nlm.2015.01.009 · Cited by 74
Metadata
- Authors
- Cantero, J. L., Atienza, M., Stickgold, R., & Hobson, J. A.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-01
- Volume
- 25
- Issue
- 2
- Pages
- 238-245
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2101885825
- Cited by
- 54
- References
- 0
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nightcap: A Reliable System for Determining Sleep Onset Latency. https://app.cochat.ai/papers/10.1093/sleep/25.2.238
- The paper
- Cantero, J. L., Atienza, M., Stickgold, R., & Hobson, J. A. (2002). Nightcap: A Reliable System for Determining Sleep Onset Latency. Sleep. https://doi.org/10.1093/sleep/25.2.238
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.