Validation of a New System of Tracheal Sound Analysis for the Diagnosis of Sleep Apnea-Hypopnea Syndrome
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVES: To evaluate the validity of a novel method of using tracheal sound analysis for the diagnosis of sleep apnea-hypopnea syndrome. DESIGN: Retrospective analysis in consecutive patients. SETTING: A sleep clinic in a general hospital. PATIENTS: A total of 383 patients who were referred for suspected sleep apnea-hypopnea syndrome and underwent diagnostic polysomnography with sufficient quality. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: Ordinary polysomnography with simultaneous tracheal sound recording was performed. The apnea-hypopnea index (AHI) was calculated as the number of apnea and hypopnea events per hour of sleep. Tracheal sounds were digitized and recorded as power spectra. An automated computer program detected transient falls (TS-dip) in the time series of moving average of the logarithmic power of tracheal sound. We defined the tracheal sound-respiratory disturbance index (TS-RDI) as the number of TS-dips per hour of examination. We also calculated the oxygen desaturation index (the number of SaO2 dips of at least 4% per hour of examination). The TS-RDI highly correlated with AHI (r = 0.93). The mean (+/- SD) difference between the TS-RDI and AHI was -8.4 +/- 10.4. The diagnostic sensitivity and specificity of the TS-RDI when the same cutoff value was used as for AHI were 93% and 67% for the AHI cutoff value of 5 and 79% and 95% for the AHI cutoff value of 15. The agreement between the TS-RDI and AHI was better than that between the oxygen desaturation index and AHI. CONCLUSIONS: The fully automated tracheal sound analysis demonstrated a relatively high performance in the diagnosis of sleep apnea-hypopnea syndrome. We think that this method is useful for the portable monitoring of sleep apnea-hypopnea syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Cited by
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Auscultation of the respiratory system
Sarkar, M., Madabhavi, I., Niranjan, N., & Dogra, M. (2015) · Annals of Thoracic Medicine · doi:10.4103/1817-1737.160831 · Cited by 362
Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring
de Oliveira, A. C. T., Martinez, D., Vasconcelos, L. F. T., Cadaval Gonçalves, S., do Carmo Lenz, M., Costa Fuchs, S., Gus, M., de Abreu-Silva, E. O., Beltrami Moreira, L., & Danni Fuchs, F. (2009) · Chest · doi:10.1378/chest.08-1859 · Cited by 129
Obstructive Sleep Apnea Screening Using a Piezo-Electric Sensor
Erdenebayar, U., Park, J.-U., Jeong, P., & Lee, K.-J. (2017) · Journal of Korean Medical Science · doi:10.3346/jkms.2017.32.6.893 · Cited by 31
Metadata
- Authors
- Nakano, H., Hayashi, M., Ohshima, E., Nishikata, N., & Shinohara, T.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-08
- Volume
- 27
- Issue
- 5
- Pages
- 951-957
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W36564834
- Cited by
- 103
- References
- 3
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.