The DOI matches its Crossref record.
A Novel Adaptive Wrist Actigraphy Algorithm for Sleep-Wake Assessment in Sleep Apnea Patients
Abstract
STUDY OBJECTIVES: Current actigraphic algorithms are relatively less accurate in detecting sleep and wake in sleep apnea patients than in people without sleep apnea. In the current study, we attempted to validate a novel automatic algorithm, which was developed for actigraphic studies in normal subjects and patients with obstructive sleep apnea by comparing it on an epoch-by-epoch basis to standard polysomnography. DESIGN: Prospective cohort study. SETTING: Multicenter, university hospital, sleep laboratories. PARTICIPANTS: A total of 228 subjects from 3 different sleep centers (Skara, Boston, Haifa) participated. INTERVENTION AND MEASUREMENTS: Simultaneous recording of polysomnography and Watch_PAT100, an ambulatory device that contains a built-in actigraph. The automatic sleep/wake algorithm is based on both the quantification of motion (magnitude and duration) and the various periodic movement patterns, such as those occurring in patients with moderate to severe obstructive sleep apnea. RESULTS: The overall sensitivity and specificity to identify sleep was 89% and 69%, respectively. The agreement ranged from 86% in the normal subjects to 86%, 84%, and 80% in the patients with mild, moderate, and severe obstructive sleep apnea, respectively. There was a tight agreement between actigraphy and polysomnography in determining sleep efficiency (78.4 +/- 9.9 vs 78.8 +/- 13.4%), total sleep time (690 +/- 152 vs 690 +/- 154 epochs), and sleep latency (56.8 +/- 31.4 vs 43.3 +/- 45.4 epochs). While for most individuals the difference between the polysomnography and actigraphy was relatively small, for some there was a substantial disagreement. CONCLUSIONS: We conclude that this actigraphy algorithm provides a reasonably accurate estimation of sleep and wakefulness in normal subjects and patients with obstructive sleep apnea on an epoch-by-epoch basis. This simple method for assessment of total sleep time may provide a useful tool for the accurate quantification of obstructive sleep apnea in the home environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Martin, J. L., & Hakim, A. D. (2011) · Chest · doi:10.1378/chest.10-1872 · Cited by 603
Smith, M. T., McCrae, C. S., Cheung, J., Martin, J. L., Harrod, C. G., Heald, J. L., & Carden, K. A. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7228 · Cited by 517
Metrics of sleep apnea severity: beyond the apnea-hypopnea index
Malhotra, A., Ayappa, I., Ayas, N., Collop, N., Kirsch, D., Mcardle, N., Mehra, R., Pack, A. I., Punjabi, N., White, D. P., et al. (2021) · SLEEP · doi:10.1093/sleep/zsab030 · Cited by 489
Self-citationObstructive Sleep Apnea Devices for Out-Of-Center (OOC) Testing: Technology Evaluation
Collop, N. A., Tracy, S. L., Kapur, V., Mehra, R., Kuhlmann, D., Fleishman, S. A., & Ojile, J. M. (2011) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1328 · Cited by 427
Metadata
- Authors
- Hedner, J., Pillar, G., Pittman, S. D., Zou, D., Grote, L., & White, D. P.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12
- Volume
- 27
- Issue
- 8
- Pages
- 1560-1566
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2396760804
- Cited by
- 214
- References
- 0
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Adaptive Wrist Actigraphy Algorithm for Sleep-Wake Assessment in Sleep Apnea Patients. https://app.cochat.ai/papers/10.1093/sleep/27.8.1560
- The paper
- Hedner, J., Pillar, G., Pittman, S. D., Zou, D., Grote, L., & White, D. P. (2004). A Novel Adaptive Wrist Actigraphy Algorithm for Sleep-Wake Assessment in Sleep Apnea Patients. Sleep. https://doi.org/10.1093/sleep/27.8.1560
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.