Validation of ApneaLink as Screening Device for Cheyne-Stokes Respiration
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
STUDY OBJECTIVES: Polysomnography (PSG) is the gold standard in diagnosing sleep disordered breathing (SDB). Diagnostic analysis of SDB is time-consuming and labor-intensive and entails long waiting lists for patients. The aim of this study was to assess the validity of a flow-based screening classifier as an automated diagnostic test for Cheyne-Stokes respiration (CSR). SETTING: Sleep laboratory. PARTICIPANTS: 70 study subjects (28 with obstructive sleep apnea [OSA], 20 with CSR, 11 with CSR+OSA and 11 without SDB). MEASUREMENTS: The nasal cannula flow signal was analyzed by ApneaLink (ResMed, Sydney, Australia), based on a classifier algorithm using pattern recognition. In a simultaneous PSG, results were compared with manual scoring of respiratory events by certified sleep experts. RESULTS: For detecting CSR we obtained a sensitivity of 87.1% (95% confidence interval 75.3% to 98.9%), a specificity of 94.9% (95% confidence interval 87.9% to 100%), a positive likelihood ratio of 17.0, and a negative likelihood ratio of 0.14. The area under the curve (AUC) of the according receiver operating characteristic (ROC) curve was 93.4%. This resulted in an accuracy of 91.4% for identifying CSR. CONCLUSION: In this study we demonstrated that the screening classifier was able to detect CSR with high diagnostic accuracy. Hence, ApneaLink equipped with CSR classifier is an appropriate screening tool which may help to prioritize patients with CSR for PSG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oldenburg, O., Lamp, B., Faber, L., Teschler, H., Horstkotte, D., & Töpfer, V. (2007) · European Journal of Heart Failure · doi:10.1016/j.ejheart.2006.08.003 · Cited by 756
Self-citation
Cited by
Obstructive sleep apnea and acute myocardial infarction severity: ischemic preconditioning?
Shah, N., Redline, S., Yaggi, H. K., Wu, R., Zhao, C. G., Ostfeld, R., Menegus, M., Tracy, D., Brush, E., Appel, W. D., et al. (2013) · Sleep and Breathing · doi:10.1007/s11325-012-0770-7 · Cited by 167
Portable Sleep Monitoring for Diagnosing Sleep Apnea in Hospitalized Patients With Heart Failure
Aurora, R. N., Patil, S. P., & Punjabi, N. M. (2018) · Chest · doi:10.1016/j.chest.2018.04.008 · Cited by 50
Sharma, S., Fox, H., Aguilar, F., Mukhtar, U., Willes, L., Bozorgnia, B., Bitter, T., & Oldenburg, O. (2019) · Sleep · doi:10.1093/sleep/zsz100 · Cited by 47
Savage, H. O., Khushaba, R. N., Zaffaroni, A., Colefax, M., Farrugia, S., Schindhelm, K., Teschler, H., Weinreich, G., Grueger, H., Neddermann, M., et al. (2016) · ESC Heart Failure · doi:10.1002/ehf2.12086 · Cited by 30
Self-citationAraújo, I., Marques, F., André, S., Araújo, M., Marques, S., Ferreira, R., Moniz, P., Proença, M., Borrego, P., & Fonseca, C. (2018) · Sleep and Breathing · doi:10.1007/s11325-017-1607-1 · Cited by 18
Metadata
- Authors
- Weinreich, G., Armitstead, J., Töpfer, V., Wang, Y.-M., Wang, Y., & Teschler, H.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-04
- Volume
- 32
- Issue
- 4
- Pages
- 553-557
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2125063507
- Cited by
- 47
- References
- 1
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of ApneaLink as Screening Device for Cheyne-Stokes Respiration. https://app.cochat.ai/papers/10.1093/sleep/32.4.553
- The paper
- Weinreich, G., Armitstead, J., Töpfer, V., Wang, Y.-M., Wang, Y., & Teschler, H. (2009). Validation of ApneaLink as Screening Device for Cheyne-Stokes Respiration. Sleep. https://doi.org/10.1093/sleep/32.4.553
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.