Cephalometric Analyses and Flow-Volume Loops in Obstructive Sleep Apnea Patients
Open accessAbstract
Fifteen patients with obstructive sleep apnea syndrome (OSAS) and 10 controls were studied. Polygraphic monitoring during sleep confirmed the presence or absence of OSAS. Ten OSAS patients and five controls had cephalometric analysis and 12 OSAS patients and five controls had a flow-volume loop study during wakefulness. Seven OSAS patients were submitted to both analyses. Flow-volume loops were unable to detect extrathoracic airway obstruction in six out of 12 OSAS patients. One control was found with positive results. Six out of seven subjects with positive flow-volume loops were overweight (greater than or equal to 30% ideal weight). Cephalograms were very useful in demonstrating mandibular deficiencies in OSAS patients. The length of the soft palate and the position of the hyoid bone, together with the measurement of the posterior airway space, are criteria of great interest in OSAS patients. Cephalometric analysis is recommended in all OSAS patients scheduled for surgical procedure. None of these tests, however, whether alone or in combination, is capable of identifying all cases of OSAS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tweed, C. H. (1946) · American Journal of Orthodontics and Oral Surgery · doi:10.1016/0096-6347(46)90001-4 · Cited by 344
The effect of mandibular osteotomy in three patients with hypersomnia sleep apnea
Kuo, P. C., West, R. A., Bloomquist, D. S., & Rw, M. (1979) · Oral Surgery Oral Medicine Oral Pathology · doi:10.1016/0030-4220(79)90063-x · Cited by 135
Sleep apnea syndrome: correction with surgical advancement of the mandible.
Bear, S. E., & Priest, J. H. (1980) · PubMed · Cited by 129
Mandibular advancement and obstructive sleep apnea syndrome.
Powell, N. B., Guilleminault, C., Riley, R. W., & Smith, L. (1983) · PubMed · Cited by 94
Self-citationCraniofacial templates for orthodontic case analysis
Popovich, F., & Thompson, G. W. (1977) · American Journal of Orthodontics · doi:10.1016/0002-9416(77)90244-5 · Cited by 94
The Detection of Sleep Apnea in the Awake Patient: The 'Saw-Tooth' Sign
Sanders, M. H. (1981) · JAMA · doi:10.1001/jama.245.23.2414 · Cited by 94
Abnormal inspiratory flow-volume curves in patients with sleep-disordered breathing.
Haponik, E. F., Bleecker, E. R., Allen, R. P., Smith, P. L., & Kaplan, J. (1981) · PubMed · doi:10.1164/arrd.1981.124.5.571 · Cited by 75
A simplified method of taking radiographs for cephalometric analysis.
Bean, L. R., Kramer, D., & Khouw, F. E. (1970) · PubMed · Cited by 23
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
(2006) · Anesthesiology · doi:10.1097/00000542-200605000-00026 · Cited by 1,188
A Cause of Excessive Daytime Sleepiness
Guilleminault, C., Stoohs, R., Clerk, A., Cetel, M., & Maistros, P. (1993) · Chest · doi:10.1378/chest.104.3.781 · Cited by 897
Self-citation(2014) · Anesthesiology · doi:10.1097/aln.0000000000000053 · Cited by 676
Metadata
- Authors
- Riley, R., Guilleminault, C., Herran, J., & Powell, N.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1983-12
- Volume
- 6
- Issue
- 4
- Pages
- 303-311
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W1686990622
- Cited by
- 488
- References
- 8
- FWCI
- 7.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.