Are Microarousals Preceded by Electroencephalographic Slow Wave Synchronization Precursors of Confusional Awakenings?
The DOI matches its Crossref record.
Abstract
The number of microarousals preceded by electroencephalographic (EEG) slow wave synchronization (MAS) and the number not preceded by EEG slow wave synchronization (K-complexes and/or delta groups) (MA) were analyzed during the first night of sleep in nine young patients with somnambulism and/or sleep terrors and in eight age- and sex-matched controls. While MAs peaked in REM ad intermediate sleep, MASs appeared as a phenomenon of NREM sleep, peaking in stage 2. The number of MASs was significantly greater in all stages of NREM sleep in the patient group, but number and distribution of MAs did not differ between the two groups. In the patient group, the MASs occurred in slow wave sleep (stages 3-4 of each sleep cycle); in controls, MASs occurred infrequently. MASs were frequently associated with automatic chewing movements. The higher frequency of microarousals in the patient group did not result in an increase in time awake during the night. The increase in number of microarousals supports Broughton's hypothesis of the presence of some "arousal disorder" in somnambulism and/or sleep terrors. MASs may be predictive markers of ensuing confusional awakenings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The nature of arousal in sleep
Halász, P., Terzano, M., Parrino, L., & Bódizs, R. (2004) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2004.00388.x · Cited by 529
Self-citationN eurobiological M echanisms I nvolved in S leep B ruxism
Lavigne, G. J., Kato, T., Kolta, A., & Sessle, B. J. (2003) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/154411130301400104 · Cited by 497
The Indications for Polysomnography and Related Procedures
Chesson, A. L., Ferber, R. A., Fry, J. M., Grigg-Damberger, M., Hartse, K. M., Hurwitz, T. D., Johnson, S., Kader, G. A., Littner, M., Rosen, G., et al. (1997) · Sleep · doi:10.1093/sleep/20.6.423 · Cited by 362
Sleep Bruxism: An Oromotor Activity Secondary to Micro-arousal
Kato, T., Rompré, P., Montplaisir, J. Y., Sessle, B. J., & Lavigne, G. J. (2001) · Journal of Dental Research · doi:10.1177/00220345010800101501 · Cited by 320
Cardiac activation during arousal in humans: further evidence for hierarchy in the arousal response
Sforza, E., Jouny, C., & Ibanez, V. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00363-1 · Cited by 317
Metadata
- Authors
- Halász, P., Ujszászi, J., & Gádoros, J.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 1985-09
- Volume
- 8
- Issue
- 3
- Pages
- 231-238
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W2419498017
- Cited by
- 73
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Are Microarousals Preceded by Electroencephalographic Slow Wave Synchronization Precursors of Confusional Awakenings? https://app.cochat.ai/papers/10.1093/sleep/8.3.231
- The paper
- Halász, P., Ujszászi, J., & Gádoros, J. (1985). Are Microarousals Preceded by Electroencephalographic Slow Wave Synchronization Precursors of Confusional Awakenings? Sleep. https://doi.org/10.1093/sleep/8.3.231
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.