CoChat

A high-density polysomnographic picture of disorders of arousal

Ratti, Pietro-Luca, Amato, Ninfa, David, Olivier, Manconi, Mauro · 2018 · Sleep
Cited by 12

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Dear Editor, We read with great interest the article of Flamand et al. “Confusional arousals during NREM sleep: evidence from intracerebral recordings” [1]. This work gives an outlook on the pathophysiology of cognitive features of non-rapid eye movement (NREM) parasomnias (disorders of arousal, DOA) and reinforces emerging concept of behavioral and cognitive manifestations of DOA to depend on widespread functional modifications of brain circuits’ dynamics rather than simply on simultaneous co-occurrence of deep sleep and arousal in different brain regions [2]. In fact, previous studies have shown that DOA episodes are preceded by increased in slow wave activity (0.25–2.0 Hz) [3], in low delta power [4] or in slow oscillations (<1 Hz) [5] and changes in brain connectivity [6]. We would like to provide additional evidence to this hypothesis and to the comprehension of DOA pathophysiology. We recorded 14 NREM parasomnia episodes during two video-poly-somnographies (one with 10-channel electroencephalography [EEG], one with 256-channel high-density EEG) in a non-medicated, otherwise healthy 22-year-old male with history of recurrent nocturnal behaviors ranging from sleepwalking, sleep talking or unconscious eating to “minor” behaviors like eyes opening, head and trunk raising and looking around. The patient had familiar history of NREM parasomnia and no history of epilepsy or febrile seizures. All the 14 episodes recorded featured chin electromyographic activation, predominantly anterior high-voltage hypersynchronous delta activity (HSDA) of around 1.5 Hz (Supplementary Figure S1B) and non-stereotyped behaviors with typical semeiologic features of DOA-associated movements of motor pattern I and II [7]: abrupt rising of his head and eyes opening, gentle head turning and looking around, nose touching, incomprehensible speech and body position changes, in variable combinations. The patient appeared confused, rapidly fell asleep again and had no morning recall of the events. Mean duration of the episodes was of 70 ± 46 seconds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/zsy162

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 12

Metadata

Authors
Ratti, P.-L., Amato, N., David, O., & Manconi, M.
Venue
Sleep
Published
2018-08-22
Volume
41
Issue
11
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2888273179
Cited by
12
References
4
FWCI
0.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A high-density polysomnographic picture of disorders of arousal. https://app.cochat.ai/papers/10.1093/sleep/zsy162
The paper
Ratti, P.-L., Amato, N., David, O., & Manconi, M. (2018). A high-density polysomnographic picture of disorders of arousal. Sleep. https://doi.org/10.1093/sleep/zsy162

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.