Single-Dose Toxicity Study of Hepatic Intra-arterial Infusion of Doxorubicin Coupled to a Novel Magnetically Targeted Drug Carrier
The DOI matches its Crossref record.
Abstract
The toxicity of a single hepatic intra-arterial administration of doxorubicin (DOX) coupled to a magnetically targeted drug carrier (MTC) was evaluated in a swine model. MTC is a microparticle composite of elemental iron and activated carbon. MTC-DOX is a new formulation of doxorubicin absorbed to the MTC and is designed for site-specific delivery to a solid tumor in the presence of an externally applied magnetic field. The magnetic field induces extravasation of MTCs through the vascular wall, leading to localization and retention in the tissue at the targeted site. Eighteen swine were assigned to 6 treatment groups, including 3 control groups (vehicle control, doxorubicin, MTC), and 3 experimental groups that received the MTC-DOX preparation. Animals were given a single administration of test article, evaluated over 28 days, and then sacrificed. Signs of toxicity were monitored via clinical status, total body weight, gross and microscopic pathology, and serum chemistries. Angiography was used to determine the extent of any embolization present. There were no adverse effects observed in the DOX-alone group. Biologically significant, treatment-related gross and microscopic lesions were limited to the targeted area of the liver only in groups receiving > or =75 mg of MTC (with or without doxorubicin). The severity of liver necrosis correlated to the severity of embolization following treatment. Doxorubicin was not freely circulating in any of the MTC-DOX groups, suggesting successful localization to the targeted site. The no-adverse-effect level (NOAEL) was determined to be the MTC-DOX low-dose group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Mahmoudi, M., Sant, S., Wang, B., Laurent, S., & Sen, T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.05.006 · Cited by 1,881
Ulbrich, K., Holá, K., Šubr, V., Bakandritsos, A., Tuček, J., & Zbořil, R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00589 · Cited by 1,730
Magnetic nanoparticles for drug delivery
Arruebo, M., Fernández-Pacheco, R., Ibarra, M. R., & Santamaría, J. (2007) · Nano Today · doi:10.1016/s1748-0132(07)70084-1 · Cited by 1,613
Metadata
- Authors
- Goodwin, S. C., Bittner, C. A., Peterson, C. L., & Wong, G.
- Venue
- Toxicological Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-03-01
- Volume
- 60
- Issue
- 1
- Pages
- 177-183
- ISSN
- 1096-0929 (ISSN-L)
- 1096-6080
- OpenAlex
- W2107553772
- Cited by
- 123
- References
- 0
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-Dose Toxicity Study of Hepatic Intra-arterial Infusion of Doxorubicin Coupled to a Novel Magnetically Targeted Drug Carrier. https://app.cochat.ai/papers/10.1093/toxsci/60.1.177
- The paper
- Goodwin, S. C., Bittner, C. A., Peterson, C. L., & Wong, G. (2001). Single-Dose Toxicity Study of Hepatic Intra-arterial Infusion of Doxorubicin Coupled to a Novel Magnetically Targeted Drug Carrier. Toxicological Sciences. https://doi.org/10.1093/toxsci/60.1.177
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.