To the Editor
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In their recent publication in Toxicological Sciences Mitchell et al. (2007) report on the lung and systemic responses to carbon nanotubes (CNT) in mice. After 14 days of inhalation exposure to a maximum of 5 mg CNT/m3, no significant lung toxicity was reported but immunological changes were noted in the spleen. These results contrast with the marked inflammatory and fibrotic lung responses reported by other investigators who used single wall CNT intratracheal (i.t.) injection in mice (Lam et al., 2004) or rats (Warheit et al., 2004), pharyngeal aspiration of single wall CNT in mice (Shvedova et al., 2005) or i.t. injection of multiwall CNT (MWCNT) in rats (Muller et al., 2005). Mitchell et al. confronted in particular their results with our finding of severe inflammatory and fibrotic lung changes after i.t. administration (Muller et al., 2005) and argued that the results of these early experiments are probably of little relevance to assess the hazard of MWCNT because they could not be reproduced upon inhalation exposure. Although this conclusion may be correct for several other reasons, we believe that it cannot be drawn from the data presented by the authors. Several major differences indeed exist between both studies. First, and most importantly, the inhalation study by Mitchell et al. (2007) was not conducted with MWCNT. The detailed and careful physicochemical characterization of the material included in the publication indeed indicates that herringbone carbon nanofibers, not MWCNT, were used (transmission electron microscopy [TEM] image on Fig. 2B in the publication). This herringbone carbonaceous material is not a nanotube but a nanofiber (Melechko et al., 2005). Although MWCNT consists of multiple graphene sheets rolled into concentric cylinders such that the lattices of carbon atoms remain continuous around the circumference and parallel to the axis of the nanotube, the herringbone structure comprises graphite layers arranged at a variable angle to the axis of the filament, forming a stacked and discontinuous arrangement of cones. Carbon nanofibers are intrinsically less perfect than MWCNT as they have graphitic edge terminations exposed on their surface. They have many properties in common with carbon nanotubes and share some potential applications (e.g., gas storage, filtration). They do, however, not share all of the properties of CNT, mainly those based on their structure (e.g., mechanical strength of carbon nanofibers is several orders of magnitude lower than that of CNT) (Melechko et al., 2005). Thus, the MWCNT picture shown in Fig. 1 of the publication by Mitchell et al. (2007) is misleading because it represents a material that was not tested in this study. For the same reason, the title of the publication is also misleading. (A) Herringbone carbon nanofibers used by Mitchell et al. (2007) TEM image. (B) Multiwall carbon nanotubes used by Muller et al. (2005) TEM image. The doses of material tested in both studies were also significantly different. The mass dose of MWCNT that we instilled varied between 2 and 20 mg/kg b.w., whereas the maximal calculated deposited dose of nanofibers was 2.7 mg/kg b.w. When examining the histological sections obtained at the end of the exposure period (Fig. 7), the actual deposited dose may probably even be lower. This could be easily checked by measuring the particle content in lung tissue by using one of the metallic contaminants as a tracer. Moreover, the specific surface area (s.s.a.) of the nanofibers was 100 m2/g, whereas our MWCNT had an s.s.a. of about 300 m2/g. Because the prevailing view is that surface reactivity and hence surface area are important determinants of the toxicity for low solubility particles (Lison et al., 1997; Donaldson et al., 2006; Monteiller et al., 2007), the maximal doses tested varied by a factor of at least 20 between both studies. The materials were not tested in the same species. While nanofibers were tested in mice, MWCNT were tested in rats which usually appear more sensitive to inhaled particles than mice (Elder et al., 2005). The observation period also differed between both studies: 60 versus 14 days for MWCNT and nanofibers, respectively. As acknowledged by Mitchell et al. (2007), it cannot be excluded that effects of nanofibers could appear at later time points. The biopersistence of tested materials in the lung is another important determinant of toxicity. We found that a substantial fraction of instilled MWCNT was still present after 60 days in the rat lung. Although the biopersistence of herringbone nanofibers was not assessed in mice, the apparently very low burden of material on the lung sections shown in Fig. 7 may also suggest that this material was rapidly cleared from the lung. We conclude that: (1) A detailed physicochemical characterization of the tested material, including a TEM analysis, is essential to adequately characterize the hazard of inhaled particles (Oberdörster et al., 2005). This appears eve
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Unusual inflammatory and fibrogenic pulmonary responses to single-walled carbon nanotubes in mice
Shvedova, A. A., Kisin, E. R., Mercer, R., Murray, A. R., Johnson, V. J., Potapovich, A. I., Tyurina, Y. Y., Gorelik, O., Arepalli, S., Schwegler-Berry, D., et al. (2005) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00084.2005 · Cited by 1,312
Donaldson, K., Aitken, R., Tran, L., Stone, V., Duffin, R., Forrest, G., & Alexander, A. (2006) · Toxicological Sciences · doi:10.1093/toxsci/kfj130 · Cited by 1,167
Respiratory toxicity of multi-wall carbon nanotubes
Muller, J., Huaux, F., Moreau, N., Misson, P., Heilier, J.-F., Delos, M., Arras, M., Fonseca, A., Nagy, J. B., & Lison, D. (2005) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2005.01.008 · Cited by 1,123
Self-citation
Cited by
Bhirde, A. A., Patel, V., Gavard, J., Zhang, G., Sousa, A. A., Masedunskas, A., Leapman, R. D., Weigert, R., Gutkind, J. S., & Rusling, J. F. (2009) · ACS Nano · doi:10.1021/nn800551s · Cited by 853
A pilot toxicology study of single-walled carbon nanotubes in a small sample of mice
Schipper, M. L., Nakayama-Ratchford, N., Davis, C. R., Kam, N. W. S., Chu, P., Liu, Z., Sun, X., Dai, H., & Gambhir, S. S. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.68 · Cited by 744
Carbon nanotubes for delivery of small molecule drugs
Wong, B. S., Yoong, S. L., Jagusiak, A., Panczyk, T., Ho, H. K., Ang, W. H., & Pastorin, G. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.08.005 · Cited by 585
Mouse pulmonary dose- and time course-responses induced by exposure to multi-walled carbon nanotubes
Porter, D. W., Hubbs, A. F., Mercer, R. R., Wu, N., Wolfarth, M. G., Sriram, K., Leonard, S., Battelli, L., Schwegler-Berry, D., Friend, S., et al. (2010) · Toxicology · doi:10.1016/j.tox.2009.10.017 · Cited by 538
Mechanisms of pulmonary toxicity and medical applications of carbon nanotubes: Two faces of Janus?
Shvedova, A. A., Kisin, E. R., Porter, D., Schulte, P., Kagan, V. E., Fadeel, B., & Castranova, V. (2009) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2008.10.009 · Cited by 336
Metadata
- Authors
- Lison, D., & Muller, J.
- Venue
- Toxicological Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2007-09-25
- Volume
- 101
- Issue
- 1
- Pages
- 179-180
- ISSN
- 1096-0929 (ISSN-L)
- 1096-6080
- OpenAlex
- W1749717806
- Cited by
- 38
- References
- 3
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: To the Editor. https://app.cochat.ai/papers/10.1093/toxsci/kfm249
- The paper
- Lison, D., & Muller, J. (2008). To the Editor. Toxicological Sciences. https://doi.org/10.1093/toxsci/kfm249
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.