Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 165

The DOI matches its Crossref record.

A human tissue‐engineered vascular media: a new model for pharmacological studies of contractile responses

L’HEUREUX, NICOLAS, STOCLET, JEAN‐CLAUDE, AUGER, FRANÇOIS A., LAGAUD, GUY JEAN‐LOUIS, GERMAIN, LUCIE, ANDRIANTSLTOHAINA, RAMAROSON · 2001 · The FASEB Journal

Abstract

Our method for producing tissue‐engineered blood vessels based exclusively on the use of human cells, i.e., without artificial scaffolding, has previously been described (1). In this report, a tissue‐engineered vascular media (TEVM) was specifically produced for pharmacological studies from cultured human vascular smooth muscle cells (VSMC). The VSMC displayed a differentiated phenotype as demonstrated by the re‐expression of VSMC‐specific markers and actual tissue contraction in response to physiological stimuli. Because of their physiological shape and mechanical strength, rings of human TEVM could be mounted on force transducers in organ baths to perform standard pharmacological experiments. Concentration‐response curves to vasoconstrictor agonists (histamine, bradykinin, ATP, and UTP) were established, with or without selective antagonists, allowing pharmacological characterization of receptors (H 1 ,B 2 , and P 2Y1 , and pyrimidinoceptors). Sustained agonist‐induced contractions were associated with transient increases in cytosolic Ca 2+ concentration, suggesting sensitization of the contractile machinery to Ca 2+ . ATP caused both Ca 2+ entry and Ca 2+ release from a ryanodine‐ and caffeine‐sensitive store. Increased cyclic AMP or cyclic GMP levels caused relaxation. This human TEVM displays many of functional characters of the normal vessel from which the cells were originally isolated, including contractile/relaxation responses, cyclic nucleotide sensitivity, and Ca 2+ handling mechanisms comparable to those of the normal vessel from which the cells were originally isolated. These results demonstrate the potential of this human model as a versatile new tool for pharmacological research.—L Heureux, N., Stoclet, J.‐C., Auger, F. A., Lagaud, G. J.‐L., Germain, L., Andriantsitohaina, R. A human tissue‐engineered vascular media: a new model for pharmacological studies of contractile responses. FASEB J. 15, 515‐524 (2001)

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1096/fj.00-0283com

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 165

Metadata

Authors
L’HEUREUX, N., STOCLET, J., AUGER, F. A., LAGAUD, G. J., GERMAIN, L., & ANDRIANTSLTOHAINA, R.
Venue
The FASEB Journal
Publisher
Wiley
Published
2001-02
Volume
15
Issue
2
Pages
515-524
ISSN
  • 0892-6638 (ISSN-L)
  • 1530-6860
OpenAlex
W2098251659
Cited by
165
References
0
FWCI
6.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A human tissue‐engineered vascular media: a new model for pharmacological studies of contractile responses. https://app.cochat.ai/papers/10.1096/fj.00-0283com
The paper
L’HEUREUX, N., STOCLET, J., AUGER, F. A., LAGAUD, G. J., GERMAIN, L., & ANDRIANTSLTOHAINA, R. (2001). A human tissue‐engineered vascular media: a new model for pharmacological studies of contractile responses. The FASEB Journal. https://doi.org/10.1096/fj.00-0283com

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.