Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Effect of the Intensity of Transcutaneous Acupoint Electrical Stimulation on the Postoperative Analgesic Requirement

Wang, Baoguo, Tang, Jun, White, Paul F., Naruse, Robert, Sloninsky, Alexander, Kariger, Robert, Gold, Julian, Wender, Ronald H.·1997·Anesthesia & Analgesia

Abstract

Given the inherent side effects associated with both opioid and nonopioid analgesic drugs, a nonpharmacologic therapy that could decrease the need for analgesic medication would be valuable. We designed a sham-controlled study to assess the effect of the intensity of transcutaneous acupoint electrical stimulation (TAES) on postoperative patient-controlled analgesia (PCA) requirement for hydromorphone (HM), the incidence of opioid-related side effects, and the recovery profile after lower abdominal surgery. One hundred one healthy consenting women undergoing lower abdominal procedures with a standardized general anesthetic technique were randomly assigned to one of four postoperative analgesic treatment regimens: Group I (n = 26) PCA only; Group II (n = 25), PCA + sham-TAES (no electrical stimulation); Group III (n = 25), PCA + low-TAES (4-5 mA of electrical stimulation); Group IV (n = 25), PCA + high-TAES (9-12 mA of electrical stimulation). The PCA device was programmed to deliver HM, 0.2-0.4 mg intravenously boluses "on demand," with a minimum lockout interval of 10 min. The TAES skin electrodes were placed at the Hegu acupoint on the nondominant hand and on both sides of the surgical incision. The TAES frequency was set in the dense-and-disperse mode, alternating at 2 Hz and 100 Hz every 3 s, with stimulation of the hand and incision alternated every 6 s. The patients in Groups II-IV were instructed to use TAES every 2 h for 30 min while awake. After discontinuation of PCA, oral pain medications were administered on demand. The postoperative PCA-HM requirement, pain scores, opioid-related side effects, and requirements for antiemetic and antipruritic medication were recorded. High-TAES decreased the HM requirement by 65% and reduced the duration of PCA therapy, as well as the incidence of nausea, dizziness, and pruritus. Low-TAES produced a 34% decrease in the HM requirement compared with only 23% in the "sham" TAES group. We conclude that high-TAES produced a significant decrease in the PCA opioid requirement and opioid-related side effects after low intraabdominal surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-199708000-00029

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 216

Metadata

Authors
Wang, B., Tang, J., White, P. F., Naruse, R., Sloninsky, A., Kariger, R., Gold, J., & Wender, R. H.
Venue
Anesthesia & Analgesia
Published
1997-08
Volume
85
Issue
2
Pages
406-413
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2147281871
Cited by
216
References
1
FWCI
3.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of the Intensity of Transcutaneous Acupoint Electrical Stimulation on the Postoperative Analgesic Requirement. https://app.cochat.ai/papers/10.1097/00000539-199708000-00029
The paper
Wang, B., Tang, J., White, P. F., Naruse, R., Sloninsky, A., Kariger, R., Gold, J., & Wender, R. H. (1997). Effect of the Intensity of Transcutaneous Acupoint Electrical Stimulation on the Postoperative Analgesic Requirement. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-199708000-00029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.