Intraoperative Transesophageal Echocardiography for Pediatric Patients with Congenital Heart Disease
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Intraoperative transesophageal echocardiography (TEE) has been used in adult cardiac patients since the mid-1980s for the evaluation of valvular repair [1,2] and prosthetic valve function [3,4], and for monitoring of myocardial ischemia [5,6] and left ventricular preload [7-9]. Immediate detection of inadequate surgical repairs by TEE improves surgical corrections, thereby avoiding subsequent reoperations and reducing morbidity, mortality, and cost [10]. Until 1990, intraoperative evaluation of infants and children undergoing congenital heart surgery was not feasible with TEE because probe sizes were too large for most children. The subsequent development of miniaturized probes has generated a number of studies, which have demonstrated that TEE can be performed safely in the pediatric population and provide substantial benefit as well [11-15]. This review focuses on the evolution of intraoperative echocardiography for the evaluation of congenital heart surgery and the current practice of pediatric TEE in the operating room (OR). Our goal is to provide a reference source to those involved in the perioperative management of infants and children with congenital heart disease. History of Pediatric Intraoperative Epicardial Echocardiography One of the first demonstrations of the use of intraoperative echocardiography to direct specific details of corrective congenital heart surgery was provided by Ungerleider et al. [16]. They applied transducers covered in sterile latex directly to the anterior surface of the heart to assess ventricular function before and after cardiopulmonary bypass (CPB) and to document the adequacy of the surgical repair before leaving the OR [16]. Eighteen consecutive patients undergoing surgical repair of atrioventricular septal defects were evaluated by epicardial imaging pre- and postbypass. Imaging before CPB demonstrated morphologic features not previously appreciated in 7 of 18 patients (39%) and, after bypass, revealed significant residual shunts in 2 of 18 patients (11%). These findings "directed specific and efficient repair immediately so that all patients left the operating room with documented surgically acceptable results. Comparison of ventricular function between pre- and post-bypass studies enabled appropriate application of pharmacologic agents in the operating room if necessary." This landmark article by a leading congenital heart center team established that, in complex congenital heart surgery, intraoperative echocardiography could guide specific surgical or anesthetic adjustments to optimize outcome. These results substantiated those of Gussenhoven et al. [17] and were also documented in a larger series of 328 pediatric patients undergoing congenital heart surgery [18]. More recently, a study from Duke University described the usefulness of epicardial imaging for evaluation of patients undergoing surgical repair of tetralogy of Fallot [19]. These investigators concluded that postrepair identification of sizable residual abnormalities by epicardial echocardiography indicated that a reestablishment of CPB was required. This report and others [20] underscore the useful role of epicardial echocardiography in the repair of congenital heart disease. Some medical centers still prefer this imaging approach to TEE, but it requires participation and some experience in epicardial echocardiography by the surgeon. It also excludes others who might be independent advocates for patients from judgments about the adequacy of repair. History of Pediatric Intraoperative TEE The first experience with pediatric intraoperative TEE was described by Cyran et al. [21] in 1989 in children as young as 7.5 yr of age using an adult-sized probe. This report documented that this technique was useful for evaluating surgical repair of congenital heart lesions. The first probe specially designed for infants weighing as little as 3 kg was subsequently designed by Kyo et al. [22] and Omoto et al. [23] with the Aloka Company (UST 5234-5; Aloka/Corometrics, Tokyo, Japan). This was a single-plane, 5-MHz, 26-element, phased array probe with a maximal diameter of 6.9 mm. Reports regarding this probe appeared from around the world in the early 1990s, documenting the accuracy, immediacy, and feasibility of TEE in the assessment of pediatric surgical repairs [11-14,24]. Initial experience and comparative studies showed that TEE might improve the diagnostic accuracy in some patients relative to precordial echocardiography and that it had the advantage of accuracy equal to that obtained using epicardial imaging [24-30]. However, the described use of TEE had some limitations. For example, it failed to detect the exact size and location of lesions involving the right ventricular outflow tract. Despite the limitations of TEE, these studies [25-30] and others suggested that, compared with epicardial echocardiography, TEE did not interrupt surgery, cause potential dysrhythmias or hypotension, or increase the infection
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muhiudeen, I. A., Roberson, D. A., Silverman, N. H., Haas, G., Turley, K., & Cahalan, M. K. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90320-o · Cited by 100
Self-citation
Cited by
Eltzschig, H. K., Rosenberger, P., Löffler, M., Fox, J. A., Aranki, S. F., & Shernan, S. K. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2007.11.015 · Cited by 265
Ayres, N. A., Miller-Hance, W., Fyfe, D. A., Stevenson, J. G., Sahn, D. J., Young, L. T., Minich, L. L., Kimball, T. R., Geva, T., Smith, F. C., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.11.004 · Cited by 194
Self-citationBettex, D. A., Schmidlin, D., Bernath, M.-A., Pr??tre, R., Hurni, M., Jenni, R., Chassot, P.-G., & Schmid, E. R. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000081794.31004.18 · Cited by 71
Dragulescu, A., Golding, F., Van Arsdell, G., Caldarone, C., Mertens, L., Al-Radi, O., & Lee, K.-J. (2012) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.06.010 · Cited by 35
Metadata
- Authors
- Muhiudeen Russell, I. A., Miller-Hance, W. C., & Silverman, N. H.
- Venue
- Anesthesia & Analgesia
- Published
- 1998-11
- Volume
- 87
- Issue
- 5
- Pages
- 1058-1076
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2080368749
- Cited by
- 78
- References
- 1
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intraoperative Transesophageal Echocardiography for Pediatric Patients with Congenital Heart Disease. https://app.cochat.ai/papers/10.1097/00000539-199811000-00017
- The paper
- Muhiudeen Russell, I. A., Miller-Hance, W. C., & Silverman, N. H. (1998). Intraoperative Transesophageal Echocardiography for Pediatric Patients with Congenital Heart Disease. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-199811000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.