Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 185

The DOI matches its Crossref record.

Cervical Spine Motion During Airway Management: A Cinefluoroscopic Study of the Posteriorly Destabilized Third Cervical Vertebrae in Human Cadavers

Brimacombe, Joseph, Keller, Christian, Künzel, Karl H., Gaber, Othmar, Boehler, Michael, Pühringer, Fredrich · 2000 · Anesthesia & Analgesia

Abstract

UNLABELLED: We conducted a randomized, controlled, crossover study to determine cervical spine motion for six airway management techniques in human cadavers with a posteriorly destabilized third cervical (C-3) vertebra. A destabilized C-3 segment was created in 10 cadavers (6-24 h postmortem). Cervical motion was recorded by continuous lateral fluoroscopy. The following airway management techniques were performed in random order on each cadaver with manual in-line stabilization applied: face mask ventilation (FM), laryngoscope-guided orotracheal intubation (OETT), fiberscope-guided nasal intubation (FOS-NETT), esophageal tracheal Combitube((R)) (Kendall-Sheridan, Neustadt, Germany) insertion (ETC), intubating laryngeal mask insertion with fiberscope-guided tracheal intubation (ILM-OETT), and laryngeal mask airway insertion (LMA). Afterward, maximum head-neck flexion (FLEX-MAX) and maximum head-neck extension (EXT-MAX) without manual in-line stabilization was performed to determine maximum motion. The maximum posterior displacement of C-3 and the maximum segmental sagittal motion of C2-3 were determined. There was a significant increase in posterior displacement for the FM (1.9 +/- 1.2 mm, P: < 0.01), OETT (2.6 +/- 1.6 mm, P: < 0.0001), ETC (3.2 +/- 1.6 mm, P: < 0.0001), ILM-OETT (1.7 +/- 1.3 mm, P: < 0. 01), LMA (1.7 +/- 1.3 mm, P: < 0.01), FLEX-MAX (3.7 +/- 1.9 mm, P: < 0.0001), EXT-MAX (1.8 +/- 1.7, P: < 0.01), however, not for FOS-NETT (0.1 +/- 0.7 mm). Posterior displacement was less for the ILM-OETT and LMA than for the ETC (both P: < 0.04). There were no significant increases in segmental sagittal motion with any airway manipulation other than with FLEX-MAX (-4.5 +/- 4.0 degrees, P: < 0.01). Posterior displacement was similar to FLEX-MAX for the OETT and ETC; however, it was less for the FM, FOS-NETT, ILM-OETT, and LMA (all P: < 0.01). Posterior displacement was similar to EXT-MAX for all airway manipulations other than for FOS-NETT (P: < 0.001). For cervical motion and the techniques tested, the safest method of airway management in a patient with a posteriorly destabilized C-3 segment is FOS-NETT. LMA devices may be preferable to the ETC. IMPLICATIONS: In the cadaver model of a destabilized third cervical vertebrae, significant displacement of the injured segment occurs during airway management with the face mask, laryngoscope-guided oral intubation, the esophageal tracheal Combitube (Kendall-Sheridan, Neustadt, Germany), the intubating and standard laryngeal mask airway; but not with fiberscope-guided nasal intubation. For cervical motion and the techniques tested, the safest airway technique with this injury is fiberscope-guided nasotracheal intubation. Laryngeal mask devices are preferable to the esophageal tracheal Combitube.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200011000-00041

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Brimacombe, J., Keller, C., Künzel, K. H., Gaber, O., Boehler, M., & Pühringer, F.
Venue
Anesthesia & Analgesia
Published
2000-11
Volume
91
Issue
5
Pages
1274-1278
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1988889934
Cited by
185
References
0
FWCI
6.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cervical Spine Motion During Airway Management: A Cinefluoroscopic Study of the Posteriorly Destabilized Third Cervical Vertebrae in Human Cadavers. https://app.cochat.ai/papers/10.1097/00000539-200011000-00041
The paper
Brimacombe, J., Keller, C., Künzel, K. H., Gaber, O., Boehler, M., & Pühringer, F. (2000). Cervical Spine Motion During Airway Management: A Cinefluoroscopic Study of the Posteriorly Destabilized Third Cervical Vertebrae in Human Cadavers. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200011000-00041

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.