Colloids Versus Crystalloids and Tissue Oxygen Tension in Patients Undergoing Major Abdominal Surgery
Abstract
UNLABELLED: The effects of intravascular volume replacement regimens on tissue oxygen tension (ptiO(2)) are not definitely known. Forty-two consecutive patients scheduled for elective major abdominal surgery were prospectively randomized to receive either 6% hydroxyethyl starch (HES) (mean molecular weight 130 kd, degree of substitution 0.4, n = 21) or lactated Ringer's solution (RL, n = 21) for intravascular volume replacement. Fluids were administered perioperatively and continued for 24 h on the intensive care unit to keep central venous pressure between 8 and 12 mm Hg. The ptiO(2) was measured continuously in the left deltoid muscle by using microsensoric implantable partial pressure of oxygen catheters after the induction of anesthesia (baseline, T0), 60 min (T1) and 120 min thereafter (T2), at the end of surgery (T3), and on the morning of the first postoperative day on the intensive care unit (T4). HES 130/0.4 2920 +/- 360 mL and 11,740 +/- 2,630 mL of RL were given to the patients within the study period. Systemic hemodynamics and oxygenation (PaO(2), PaCO(2)) did not differ significantly between the two volume groups throughout the study. From similar baseline values, ptiO(2) increased significantly in the HES-treated patients (a maximum of 59% at T4), whereas it decreased in the RL group (a maximum of -23% at T4, P < 0.05). The largest differences of ptiO(2) were measured on the morning of the first postoperative day. We conclude that intravascular volume replacement with 6% HES 130/0.4 improved tissue oxygenation during and after major surgical procedures compared with a crystalloid-based volume replacement strategy. Improved microperfusion and less endothelial swelling may be responsible for the increase in ptiO(2) in the HES 130/0.4-treated patients. IMPLICATIONS: In patients undergoing major abdominal surgery, a colloid-based (with hydroxyethyl starch [HES] 130/0.4) and a crystalloid-based (with lactated Ringer's solution [RL]) volume replacement regimen was compared regarding tissue oxygen tension (ptiO(2)) measured continuously by microsensoric implantable catheters. The ptiO(2) increased in the HES-treated (+59%) but decreased in the RL-treated (-23%) patients. Improved microcirculation may be the mechanism for the better ptiO(2) in the HES group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Abbas, S. M., & Hill, A. G. (2008) · Anaesthesia · doi:10.1111/j.1365-2044.2007.05233.x · Cited by 296
Jacob, M., Chappell, D., Hofmann-Kiefer, K., Conzen, P., Peter, K., & Rehm, M. (2007) · Der Anaesthesist · doi:10.1007/s00101-007-1235-4 · Cited by 51
Metadata
- Authors
- Lang, K., Boldt, J., Suttner, S., & Haisch, G.
- Venue
- Anesthesia & Analgesia
- Published
- 2001-08
- Volume
- 93
- Issue
- 2
- Pages
- 405-409
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2030081634
- Cited by
- 250
- References
- 0
- FWCI
- 9.63
- Type
- journal article
- Language
- en
- Status
- Retracted
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Colloids Versus Crystalloids and Tissue Oxygen Tension in Patients Undergoing Major Abdominal Surgery. https://app.cochat.ai/papers/10.1097/00000539-200108000-00034
- The paper
- Lang, K., Boldt, J., Suttner, S., & Haisch, G. (2001). Colloids Versus Crystalloids and Tissue Oxygen Tension in Patients Undergoing Major Abdominal Surgery. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200108000-00034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.