Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record.

An Evaluation of a Virtual Reality Airway Simulator

Rowe, Richard, Cohen, Ronald A. · 2002 · Anesthesia & Analgesia

Abstract

UNLABELLED: In this research, we sought to test the hypothesis that the AccuTouch Flexible Bronchoscopy Simulator (Simulator) is an effective way to teach clinicians the psychomotor skills necessary to use the fiberoptic bronchoscope as an instrument for intubating the trachea of a pediatric patient. Pediatric residents with no prior experience in fiberoptic bronchoscopy were studied. Residents performed fiberoptic intubation on children undergoing general anesthesia. Tapes of these intubations were analyzed for: time to visualization of the carina, and number and time that the bronchoscope tip hit the mucosa. Residents were then trained on the Simulator. Performance of fiberoptic intubation on a subsequent child was compared. Training on the Simulator was the only instruction that the residents received between the two cases. A control group of residents performed two consecutive intubations without training on the Simulator between cases. Residents studied an average of 17 cases, and spent 39 min on the Simulator. Performance was markedly improved after the Simulator. Time to completion of successful intubation with a bronchoscope was reduced from 5.15 to 0.88 min (P < 0.001). The number of times that the tip of the bronchoscope hit the mucosa was reduced from 21.4 to 3.0 (P < 0.001). The amount of time that the resident spent viewing the mucosa decreased from 2.24 to 0.19 min (P < 0.001). The percent of time viewing the channel of the airway increased from 58.5% to 80.4% (P = 0.004). This bronchoscopy simulator was very effective in teaching residents the psychomotor skills necessary for fiberoptic intubation. Significant improvement was seen in time to completion of endotracheal intubation, as well as other performance indicators. IMPLICATIONS: This research showed that the AccuTouch Bronchoscopy Simulator is an effective way to teach the psychomotor skills necessary to intubate the trachea of patients using a fiberoptic bronchoscope. The residents that practiced on the Simulator dramatically improved their skills compared with a control group of residents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200207000-00011

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Rowe, R., & Cohen, R. A.
Venue
Anesthesia & Analgesia
Published
2002-07
Volume
95
Issue
1
Pages
62-66
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2081645438
Cited by
192
References
0
FWCI
9.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Evaluation of a Virtual Reality Airway Simulator. https://app.cochat.ai/papers/10.1097/00000539-200207000-00011
The paper
Rowe, R., & Cohen, R. A. (2002). An Evaluation of a Virtual Reality Airway Simulator. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200207000-00011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.