CoChat

The Effects of Perioperatively Administered Colloids and Crystalloids on Primary Platelet-Mediated Hemostasis and Clot Formation

Innerhofer, Petra, Fries, Dietmar, Margreiter, Josef, Klingler, Anton, Kühbacher, Gabriele, Wachter, Bernhard, Oswald, Elgar, Salner, Erwin, Frischhut, Bernhard, Schobersberger, Wolfgang · 2002 · Anesthesia & Analgesia
Cited by 168

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

UNLABELLED: To explore whether routinely administered colloids and crystalloids influence the hemostatic system, we studied 60 patients undergoing knee replacement surgery during randomized intravascular fluid administration using 6% hydroxyethyl starch 200/0.5 (HES) or 4% modified gelatin (GEL) in addition to a basal infusion of lactated Ringer's solution (RL), or exclusively RL. In addition to routine coagulation tests, measurements of coagulation factors were performed. Also, functional measurements of the in vitro bleeding time by use of the platelet function analyzer (PFA-100 and ROTEG analysis (ROTEG(R); extrinsically and intrinsically [Ex; In] activated measurements of clotting time, CT [s]; clot formation time, CFT [s]; clot strength, A20 [mm]; fibrinogen component of the clot, FibA20 [mm]; and maximal clot elasticity) were used. Time dependency of variables was analyzed with a repeated-measures analysis of variance (all groups pooled); differences between groups were detected by comparing the calculated area under the curve (AUC(A-D)). For all variables, except ExCT, ExCFT, and InCFT, a significant time dependency was demonstrated, indicating that impaired platelet-mediated hemostasis and clot formation occurred with IV administration of fluids. Total clot strength, fibrinogen part, and clot elasticity decreased significantly more in the colloid groups than in the RL group (InA20: HES, -13.0 mm; GEL, -11.5 mm; RL, -1.3 mm; P = 0.042; FibA20: HES, -10.5 mm; GEL, -6.0 mm; RL, -1.3 mm: P < 0.0001; MCE: HES, -48; GEL, -35; RL, -15.8; P < 0.0001). The decrease in fibronectin concentrations was significantly smaller with GEL as compared with HES, whereas a weak trend toward a larger decrease in fibrinogen concentrations was observed with both colloids. Results show that colloid administration reduces final clot strength more than does RL alone, which also exhibited effects, albeit minor, on the coagulation system. The reduction in total clot strength was due to impaired fibrinogen polymerization, resulting in a decreased fibrinogen part of the clot and reduced clot elasticity. IMPLICATIONS: Our data suggest that during deliberate colloid administration, critically impaired fibrinogen polymerization and reduced fibrinogen concentrations might be reached earlier than expected. Therefore, maintaining fibrinogen concentrations seems essential when continuing blood loss is bridged by colloid infusion until transfusion triggers are reached, especially in patients already exhibiting borderline fibrinogen levels at baseline.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200210000-00012

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Innerhofer, P., Fries, D., Margreiter, J., Klingler, A., Kühbacher, G., Wachter, B., Oswald, E., Salner, E., Frischhut, B., & Schobersberger, W.
Venue
Anesthesia & Analgesia
Published
2002-10
Volume
95
Issue
4
Pages
858-865
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2125877520
Cited by
168
References
16
FWCI
7.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.