The DOI matches its Crossref record.
On the Safety of Radial Artery Cannulation
Open accessAbstract
The frequency of complications following radial artery cannulation for monitoring purposes was determined in 1,699 cardiovascular surgical patients and in 83 patients in whom cannulation was performed in another artery after failure at the radial site. Patients were examined and radial artery flow determined by a Doppler technique 1 day and 7 days after decannulation. Although partial or complete radial artery occlusion after decannulation occurred in more than 25% of the patients, no ischemic damage to the hand or disability occurred in any patient. Neither duration of cannulation nor the size or material of the cannulas were determinants of abnormal flow. Abnormal flow was significantly related to female sex, the presence of hematoma, and to the use of extracorporeal circulation. The radial arteries of 16 patients whose results of Allen's test were abnormal were cannulated and no abnormal flow or ischemia followed. In 22 patients, the ulnar artery was cannulated after multiple punctures of the ipsilateral radial artery and no ischemia followed. We conclude that in the absence of peripheral vascular disease, the Allen's test is not a predictor of ischemia of the hand during or after radial artery cannulation, that when decreased or absent radial artery flow follows cannulation it is of no clinical consequence, and that radial artery cannulation is a low-risk high-benefit monitoring technique that deserves wide clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Percutaneous radial artery approach for coronary angiography
Campeau, L. (1989) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810160103 · Cited by 892
Saito, S., Ikei, H., Hosokawa, G., & Tanaka, S. (1999) · Catheterization and Cardiovascular Interventions · doi:10.1002/(sici)1522-726x(199902)46:2<173::aid-ccd12>3.0.co;2-4 · Cited by 484
Barbeau, G. R., Arsenault, F., Dugas, L., Simard, S., & Larivière, M. M. (2004) · American Heart Journal · doi:10.1016/j.ahj.2003.10.038 · Cited by 414
Incidence and outcome of radial artery occlusion following transradial artery coronary angioplasty
Stella, P. R., Kiemeneij, F., Laarman, G. J., Odekerken, D., Slagboom, T., & van der Wieken, R. (1997) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/(sici)1097-0304(199702)40:2<156::aid-ccd7>3.0.co;2-a · Cited by 365
Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations
Brzezinski, M., Luisetti, T., & London, M. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbd416 · Cited by 354
Metadata
- Authors
- Slogoff, S., Keats, A. S., & Arlund, C.
- Venue
- Anesthesiology
- Published
- 1983-07-01
- Volume
- 59
- Issue
- 1
- Pages
- 42-47
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1978489189
- Cited by
- 355
- References
- 0
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the Safety of Radial Artery Cannulation. https://app.cochat.ai/papers/10.1097/00000542-198307000-00008
- The paper
- Slogoff, S., Keats, A. S., & Arlund, C. (1983). On the Safety of Radial Artery Cannulation. Anesthesiology. https://doi.org/10.1097/00000542-198307000-00008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.