The DOI matches its Crossref record.
Determination of Intra-abdominal Pressure Using a Transurethral Bladder Catheter: Clinical Validation of the Technique
Abstract
The determination of intra-abdominal pressures (IAP) may be useful in many clinical situations. The authors recently demonstrated in the canine model a close correlation between actual IAP and the bladder pressure measurements obtained from a transurethral catheter. The purpose of this study was to clinically validate this technique. The authors studied 16 patients, and compared IAP in three positions (supine, with compressions, and semi-erect) utilizing both direct intraperitoneal pressure monitoring and the pressure obtained with a transurethral bladder catheter. Their results demonstrated a linear relationship between the two methods described, with a mean r value of 0.95 in the supine and semi-erect positions, and 0.99 with abdominal compressions (P less than 0.0001). The authors conclude that transurethral monitoring of bladder pressure offers a safe, simple, and highly accurate method for evaluating IAP at the bedside. Studies evaluating the indication for its use in the operating room and intensive care settings appear warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
GATTINONI, L., PELOSI, P., SUTER, P. M., PEDOTO, A., VERCESI, P., & LISSONI, A. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9708031 · Cited by 900
Malbrain, M. L. N. G., Chiumello, D., Pelosi, P., Wilmer, A., Brienza, N., Malcangi, V., Bihari, D., Innes, R., Cohen, J., Singer, P., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2169-9 · Cited by 565
Intra-abdominal Pressure in the Intensive Care Unit: Clinical Tool or Toy?
Malbrain, M. (2001) · Yearbook of Intensive Care and Emergency Medicine 2001 · doi:10.1007/978-3-642-59467-0_46 · Cited by 529
Effects of the Prone Position on Respiratory Mechanics and Gas Exchange during Acute Lung Injury
PELOSI, P., TUBIOLO, D., MASCHERONI, D., VICARDI, P., CROTTI, S., VALENZA, F., & GATTINONI, L. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.2.97-04023 · Cited by 508
Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal
Malbrain, M. L. N. G. (2004) · Intensive Care Medicine · doi:10.1007/s00134-003-2107-2 · Cited by 486
Metadata
- Authors
- Iberti, T. J., Lieber, C. E., & Benjamin, E.
- Venue
- Anesthesiology
- Published
- 1989-01-01
- Volume
- 70
- Issue
- 1
- Pages
- 47-50
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2075423220
- Cited by
- 215
- References
- 0
- FWCI
- 2.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Intra-abdominal Pressure Using a Transurethral Bladder Catheter: Clinical Validation of the Technique. https://app.cochat.ai/papers/10.1097/00000542-198901000-00011
- The paper
- Iberti, T. J., Lieber, C. E., & Benjamin, E. (1989). Determination of Intra-abdominal Pressure Using a Transurethral Bladder Catheter: Clinical Validation of the Technique. Anesthesiology. https://doi.org/10.1097/00000542-198901000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.