The DOI matches its Crossref record.
A Single-blind Study of Combined Pulse Oximetry and Capnography in Children
Abstract
This single-blind study examined four levels of monitoring in 402 pediatric cases. Patients were randomly assigned to one of four groups: 1) oximeter and capnograph; 2) only oximeter; 3) only capnograph; or 4) neither oximeter nor capnograph data available to the anesthesia team. An anesthesiologist, not involved in patient care, observed all cases and continuously recorded hemoglobin oxygen saturation (Spo2), ECG, expired CO2, and the oximeter plethysmographic output. Mean age, weight, ASA physical status, airway management (mask or endotracheal tube), and anesthetic technique were similar in each group. Two-hundred sixty problems were documented in 153 patients. Fifty-nine events in 43 patients resulted in "major" desaturation (Spo2 less than or equal to 85% for greater than or equal to 30 s). Fifteen "major" capnograph events (esophageal intubation, disconnection, accidental extubation, or obstructed endotracheal tube) were observed in 11 patients; 8 of these also developed varying degrees of desaturation. One-hundred thirty "minor" desaturation events (Spo2 less than or equal to 95% for greater than 60 s) and 79 "minor" desaturation events (hypercarbaria or hypocarbia) were observed. A number of problems fulfilled criteria in multiple categories. Infants less than or equal to 6 months of age had the highest incidence of major desaturation events (18 of 65 [27%]) compared to toddlers 7-24 months of age or children greater than 24 months of age (P less than 0.001). Blinding the oximeter data increased the number of patients (12 vs. 31) experiencing major desaturation events (P = 0.003); blinding the capnograph data altered neither the frequency of desaturation events nor the incidence of major capnograph events.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Coté, C. J., Wilson, S., AMERICAN ACADEMY OF PEDIATRICS, & AMERICAN ACADEMY OF PEDIATRIC DENTISTRY (2019) · Pediatrics · doi:10.1542/peds.2019-1000 · Cited by 1,406
Self-citationBhananker, S. M., Ramamoorthy, C., Geiduschek, J. M., Posner, K. L., Domino, K. B., Haberkern, C. M., Campos, J. S., & Morray, J. P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268712.00756.dd · Cited by 720
Adverse Sedation Events in Pediatrics: A Critical Incident Analysis of Contributing Factors
Coté, C. J., Notterman, D. A., Karl, H. W., Weinberg, J. A., & McCloskey, C. (2000) · Pediatrics · doi:10.1542/peds.105.4.805 · Cited by 593
American Academy of Pediatrics, American Academy of Pediatric Dentistry, Coté, C. J., Wilson, S., & the Work Group on Sedation (2006) · Pediatrics · doi:10.1542/peds.2006-2780 · Cited by 555
Critical review of non-invasive respiratory monitoring in medical care
Folke, M., Cernerud, L., Ekström, M., & Hök, B. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348078 · Cited by 430
Metadata
- Authors
- Coté, C. J., Rolf, N., Liu, L. M. P., Goudsouzian, N. G., Ryan, J. F., Zaslavsky, A., Gore, R., Todres, I. D., Vassallo, S., Polaner, D., & Alifimoff, J. K.
- Venue
- Anesthesiology
- Published
- 1991-06-01
- Volume
- 74
- Issue
- 6
- Pages
- 980-987
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2103488053
- Cited by
- 220
- References
- 0
- FWCI
- 13.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Single-blind Study of Combined Pulse Oximetry and Capnography in Children. https://app.cochat.ai/papers/10.1097/00000542-199106000-00003
- The paper
- Coté, C. J., Rolf, N., Liu, L. M. P., Goudsouzian, N. G., Ryan, J. F., Zaslavsky, A., Gore, R., Todres, I. D., Vassallo, S., Polaner, D., & Alifimoff, J. K. (1991). A Single-blind Study of Combined Pulse Oximetry and Capnography in Children. Anesthesiology. https://doi.org/10.1097/00000542-199106000-00003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.