Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 194

The DOI matches its Crossref record.

Biochemical Markers of Anaphylactoid Reactions to Drugs Comparison of Plasma Histamine and Tryptase

Laroche, Dominique, Vergnaud, Marie-Claude, Sillard, Béatrice, Soufarapis, Henri, Bricard, Henri · 1991 · Anesthesiology

Abstract

Adverse reactions to drugs require that their mechanisms be elucidated, particularly when anaphylaxis is suspected. Early diagnosis can be achieved by plasma histamine measurements. Unfortunately, the short plasma half-life of histamine and the difficulties in handling the sample usually preclude this measurement, although a sensitive radioimmunologic kit is routinely available. It has been recently suggested that mast cell tryptase, a component of the mast cell granules, could provide an alternative to histamine determination. We have measured plasma histamine and tryptase in 19 patients who developed possible anaphylactoid reactions to anesthetic or other drugs. Eight patients had increased values for both histamine and tryptase. In 4 a muscle relaxant drug was proved responsible for the reaction. Six patients had normal levels for both substances. In each case, the clinical signs of anaphylaxis were moderate. Two patients had normal histamine and high tryptase concentrations, due to late sampling (greater than 5 h). In 2 other patients, histamine was high, with normal tryptase: in 1, muscle relaxant allergy was further demonstrated. Tryptase half-life was equal to 90 min in 3 patients. At least 15 min was necessary to reach the peak level when the responsible drug was administered intravenously. The best time for measuring tryptase was 1-2 h after the reaction (not greater than 6 h), whereas for histamine it was 10 min to 1 h. We conclude that measurement of plasma tryptase along with measurement of plasma histamine may aid in diagnosis of anaphylaxis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199112000-00004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 194

Metadata

Authors
Laroche, D., Vergnaud, M.-C., Sillard, B., Soufarapis, H., & Bricard, H.
Venue
Anesthesiology
Published
1991-12-01
Volume
75
Issue
6
Pages
945-949
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2082211592
Cited by
194
References
0
FWCI
2.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biochemical Markers of Anaphylactoid Reactions to Drugs Comparison of Plasma Histamine and Tryptase. https://app.cochat.ai/papers/10.1097/00000542-199112000-00004
The paper
Laroche, D., Vergnaud, M.-C., Sillard, B., Soufarapis, H., & Bricard, H. (1991). Biochemical Markers of Anaphylactoid Reactions to Drugs Comparison of Plasma Histamine and Tryptase. Anesthesiology. https://doi.org/10.1097/00000542-199112000-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.