The DOI matches its Crossref record.
Randomized Evaluation of Pulse Oximetry in 20,802 Patients; I: Design, Demography, Pulse Oximetry Failure Rate, and Overall Complication Rate
Open accessAbstract
BACKGROUND: Although pulse oximetry is currently in widespread use, there are few data documenting improvement in patient outcome as a result of the use of oximetry. The authors describe the study design, patient demographic findings, data validation, pulse oximetry failure rate, and overall postoperative complication rates in the first large prospective randomized multicenter clinical trial on perioperative pulse oximetry monitoring. METHODS: In five Danish hospitals, by random assignment, monitoring did or did not include pulse oximetry for patients 18 yr of age and older, whether scheduled for elective or emergency operations, or for regional or general anesthesia, except during cardiac and neurosurgical procedures. Operational definitions were established for perioperative events and postoperative complications. The data were collected preoperatively, during anesthesia, in the postanesthesia care unit, and until the day of discharge from the hospital or the seventh postoperative day. RESULTS: Of 20,802 patients, 10,312 were assigned to the oximetry group and 10,490, to the control group. In general, the demographic data, patient factors, and anesthetic agents used were distributed evenly. A slight intergroup difference was found in the distribution of age, duration of surgery, some types of surgery, and some types of anesthesia. The total failure rate of the oximetry was 2.5%, but it increased to 7.2% in patients with American Society of Anesthesiologists physical status 4 (P < 0.00001). In 14.9% of the patients, one or more events occurred in the operating room and 13.5% in the postanesthesia care unit. The overall postoperative complication rate was 9.7%. The total rates of cardiovascular and respiratory complications were 2.78% and 3.50%, respectively. Within the first seven postoperative days, 0.47% of the patients died. Anesthesia was not thought to have been solely responsible for any death, but in 7 patients (1 per 3,365), it was a possible contributory factor. CONCLUSIONS: Despite the finding of a few significant inter-group differences, the randomization was well balanced with a high validity of data. The overall postoperative complication rate was similar to that in other recent morbidity and mortality studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Long-term postoperative cognitive dysfunction in the elderly: ISPOCD1 study
Moller, J., Cluitmans, P., Rasmussen, L., Houx, P., Rasmussen, H., Canet, J., Rabbitt, P., Jolles, J., Larsen, K., Hanning, C., et al. (1998) · The Lancet · doi:10.1016/s0140-6736(97)07382-0 · Cited by 2,422
Self-citationBhananker, S. M., Ramamoorthy, C., Geiduschek, J. M., Posner, K. L., Domino, K. B., Haberkern, C. M., Campos, J. S., & Morray, J. P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268712.00756.dd · Cited by 720
Jubran, A. (2015) · Critical Care · doi:10.1186/s13054-015-0984-8 · Cited by 491
Checketts, M. R., Alladi, R., Ferguson, K., Gemmell, L., Handy, J. M., Klein, A. A., Love, N. J., Misra, U., Morris, C., Nathanson, M. H., et al. (2016) · Anaesthesia · doi:10.1111/anae.13316 · Cited by 490
Jubran, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2399-x · Cited by 401
Metadata
- Authors
- Moller, J. T., Pedersen, T., Rasmussen, L. S., Jensen, P. F., Pedersen, B. D., Ravlo, O., Rasmussen, N. H., Espersen, K., Johannessen, N. W., Cooper, J. B., Gravenstein, J. S., Chraemmer-Jorgensen, B., Wiberg-Jorgensen, F., Djernes, M., Heslet, L., & Johansen, S. H.
- Venue
- Anesthesiology
- Published
- 1993-03-01
- Volume
- 78
- Issue
- 3
- Pages
- 436-444
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2076823876
- Cited by
- 225
- References
- 0
- FWCI
- 15.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Randomized Evaluation of Pulse Oximetry in 20,802 Patients; I: Design, Demography, Pulse Oximetry Failure Rate, and Overall Complication Rate. https://app.cochat.ai/papers/10.1097/00000542-199303000-00006
- The paper
- Moller, J. T., Pedersen, T., Rasmussen, L. S., Jensen, P. F., Pedersen, B. D., Ravlo, O., Rasmussen, N. H., Espersen, K., Johannessen, N. W., Cooper, J. B., Gravenstein, J. S., Chraemmer-Jorgensen, B., Wiberg-Jorgensen, F., Djernes, M., Heslet, L., & Johansen, S. H. (1993). Randomized Evaluation of Pulse Oximetry in 20,802 Patients; I: Design, Demography, Pulse Oximetry Failure Rate, and Overall Complication Rate. Anesthesiology. https://doi.org/10.1097/00000542-199303000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.