The Effect of Cricoid Pressure on Preventing Gastric Insufflation in Infants and Children
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: The use of cricoid pressure for the possible prevention of regurgitation of gastric contents during induction of anesthesia in both adults and children has been recommended. However, equally important is the technique in possibly preventing insufflation of gas into the stomach. This study was designed to determine the efficacy of cricoid pressure application in preventing gastric gas insufflation in pediatric patients and to determine the airway pressure at which gas entered the stomach (pop-off point). METHODS: Fifty-nine patients, 2 weeks to 8 yr of age, physical status 1-4, scheduled for elective surgery, received an inhalational induction of anesthesia with halothane, N2O, and O2. A single observer used a stethoscope to auscultate over the upper abdomen for any air entry. In study I (without paralysis), the proximal airway pressure was slowly increased by gradually closing the pop-off valve on the anesthesia machine until gas was heard entering the stomach (pop-off point) or until the peak inspiratory pressure (PIP) reached 40 cm H2O. Thereafter, the pressurization procedure was repeated three times, altering the application and removal of cricoid pressure. The same patients were then paralyzed (study II), and the stomach evacuated before commencing an identical pressurization sequence with and without cricoid pressure. RESULTS: Appropriately applied cricoid pressure was 100% effective in preventing gas insufflation into the stomach of all children up to 40 cm H2O PIP with and without paralysis. In addition, paralysis significantly decreased the median pop-off point in any given patient. CONCLUSIONS: Appropriate application of cricoid pressure prevents gastric gas insufflation during airway management via mask up to 40 cm H2O PIP in infants and children. An additional benefit of cricoid pressure occurs in paralyzed patients in whom gastric insufflation occurs at lower inflation pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deakin, C. D., Nolan, J. P., Soar, J., Sunde, K., Koster, R. W., Smith, G. B., & Perkins, G. D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.017 · Cited by 2,700
Panchal, A. R., Bartos, J. A., Cabañas, J. G., Donnino, M. W., Drennan, I. R., Hirsch, K. G., Kudenchuk, P. J., Kurz, M. C., Lavonas, E. J., Morley, P. T., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000916 · Cited by 2,105
Kleinman, M. E., Chameides, L., Schexnayder, S. M., Samson, R. A., Hazinski, M. F., Atkins, D. L., Berg, M. D., de Caen, A. R., Fink, E. L., Freid, E. B., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971101 · Cited by 1,949
Neumar, R. W., Otto, C. W., Link, M. S., Kronick, S. L., Shuster, M., Callaway, C. W., Kudenchuk, P. J., Ornato, J. P., McNally, B., Silvers, S. M., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.970988 · Cited by 1,634
European Resuscitation Council Guidelines for Resuscitation 2015
Soar, J., Nolan, J. P., Böttiger, B. W., Perkins, G. D., Lott, C., Carli, P., Pellis, T., Sandroni, C., Skrifvars, M. B., Smith, G. B., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.016 · Cited by 1,503
European Resuscitation Council Guidelines for Resuscitation 2010 Section 1. Executive summary
Nolan, J. P., Soar, J., Zideman, D. A., Biarent, D., Bossaert, L. L., Deakin, C., Koster, R. W., Wyllie, J., & Böttiger, B. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.021 · Cited by 1,375
European Resuscitation Council Guidelines for Resuscitation 2015
Perkins, G. D., Handley, A. J., Koster, R. W., Castrén, M., Smyth, M. A., Olasveengen, T., Monsieurs, K. G., Raffay, V., Gräsner, J.-T., Wenzel, V., et al. (2015) · Resuscitation · doi:10.1016/j.resuscitation.2015.07.015 · Cited by 1,287
Topjian, A. A., Raymond, T. T., Atkins, D., Chan, M., Duff, J. P., Joyner, B. L., Lasa, J. J., Lavonas, E. J., Levy, A., Mahgoub, M., et al. (2020) · Circulation · doi:10.1161/cir.0000000000000901 · Cited by 1,258
Nolan, J. P., Hazinski, M. F., Billi, J. E., Boettiger, B. W., Bossaert, L., de Caen, A. R., Deakin, C. D., Drajer, S., Eigel, B., Hickey, R. W., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.002 · Cited by 695
Morrison, L. J., Deakin, C. D., Morley, P. T., Callaway, C. W., Kerber, R. E., Kronick, S. L., Lavonas, E. J., Link, M. S., Neumar, R. W., Otto, C. W., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971051 · Cited by 612
Berg, M. D., Schexnayder, S. M., Chameides, L., Terry, M., Donoghue, A., Hickey, R. W., Berg, R. A., Sutton, R. M., & Hazinski, M. F. (2010) · Pediatrics · doi:10.1542/peds.2010-2972c · Cited by 398
European Resuscitation Council Guidelines for Resuscitation 2010 Section 6. Paediatric life support
Biarent, D., Bingham, R., Eich, C., López-Herce, J., Maconochie, I., Rodríguez-Núñez, A., Rajka, T., & Zideman, D. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.012 · Cited by 354
American Heart Association (2006) · Pediatrics · doi:10.1542/peds.2006-0346 · Cited by 297
Hunt, E. A., Walker, A. R., Shaffner, D. H., Miller, M. R., & Pronovost, P. J. (2008) · Pediatrics · doi:10.1542/peds.2007-0029 · Cited by 279
American Heart Association (2006) · Pediatrics · doi:10.1542/peds.2006-0219 · Cited by 246
Kleinman, M. E., de Caen, A. R., Chameides, L., Atkins, D. L., Berg, R. A., Berg, M. D., Bhanji, F., Biarent, D., Bingham, R., Coovadia, A. H., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.971093 · Cited by 240
Rapid Sequence Induction and Intubation: Current Controversy
El-Orbany, M., & Connolly, L. A. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181d5ae47 · Cited by 239
“Moynihan et al.93 found that application of CP prevented gastric gas insufflation during mask ventilation up to 40 cm H2O PPV in infants and children.”
BackgroundBrimacombe, J. R., & Berry, A. M. (1997) · Canadian Journal of Anaesthesia · doi:10.1007/bf03014464 · Cited by 213
Deakin, C. D., Morrison, L. J., Morley, P. T., Callaway, C. W., Kerber, R. E., Kronick, S. L., Lavonas, E. J., Link, M. S., Neumar, R. W., Otto, C. W., et al. (2010) · Resuscitation · doi:10.1016/j.resuscitation.2010.08.027 · Cited by 203
No evidence for decreased incidence of aspiration after rapid sequence induction
Neilipovitz, D. T., & Crosby, E. T. (2007) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/bf03026872 · Cited by 185
ATS/ERS Statement: Raised Volume Forced Expirations in Infants: Guidelines for Current Practice
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200408-1141st · Cited by 183
“However, this practice remains controversial (33, 34) and deserves additional investigation.”
BackgroundEllis, D. Y., Harris, T., & Zideman, D. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.05.006 · Cited by 179
Kleinman, M. E., de Caen, A. R., Chameides, L., Atkins, D. L., Berg, R. A., Berg, M. D., Bhanji, F., Biarent, D., Bingham, R., Coovadia, A. H., et al. (2010) · Pediatrics · doi:10.1542/peds.2010-2972a · Cited by 86
Metadata
- Authors
- Moynihan, R. J., Brock-Utne, J. G., Archer, J. H., Feld, L. H., & Kreitzman, T. R.
- Venue
- Anesthesiology
- Published
- 1993-04-01
- Volume
- 78
- Issue
- 4
- Pages
- 652-656
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2019971969
- Cited by
- 163
- References
- 0
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.