CoChat

Comparison of Rocuronium, Succinylcholine, and Vecuronium for Rapid-sequence Induction of Anesthesia in Adult Patients

Open access
Magorian, Toni, Flannery, K. B., Miller, Ronald D. · 1993 · Anesthesiology
Cited by 443

The DOI matches its Crossref record.

Abstract

BACKGROUND: Succinylcholine has been the agent of choice when clinical conditions require emergency airway protection during a rapid-sequence induction of anesthesia. Rocuronium, a new nondepolarizing muscle relaxant with a brief onset of action, but devoid of the adverse reactions associated with succinylcholine, may be an alternative to succinylcholine. To test this hypothesis, the authors compared rocuronium with succinylcholine and vecuronium for rapid-sequence induction of anesthesia. METHODS: Fifty patients, ASA 1-3, were randomly designated to receive one of three intravenous doses of rocuronium (0.6, 0.9, and 1.2 mg/kg), vecuronium (0.1 mg/kg), or succinylcholine (1.0 mg/kg). Patients were premedicated with midazolam and fentanyl, and received 2-7 mg/kg thiopental for induction of anesthesia. Sixty seconds after receiving a muscle relaxant, intubation of the trachea was attempted by a clinician who was blinded to the muscle relaxant administered. Neuromuscular monitoring was established before administration of the muscle relaxant. The time from injection of muscle relaxant until complete ablation of T1 (onset) and recovery of T1 to 25% (duration) were recorded. Tracheal intubating conditions were evaluated, and the presence or absence of fasciculations was noted. RESULTS: Onset times for patients receiving 0.9 mg/kg (75 +/- 28 s) and 1.2 mg/kg rocuronium (55 +/- 14 s), and succinylcholine (50 +/- 17 s) were similar. Onset times for the groups given 0.6 mg/kg rocuronium (89 +/- 33 s) and vecuronium (144 +/- 39 s) were significantly longer. Clinical duration of action was longest with 1.2 mg/kg rocuronium, similar with 0.6 and 0.9 mg/kg rocuronium, and vecuronium, and least with succinylcholine. CONCLUSIONS: There is a dose-dependent decrease in onset time with rocuronium. The onset times for the two larger doses of rocuronium were similar to that for succinylcholine, but clinical duration of action with rocuronium was significantly longer. The brief onset time achieved with rocuronium indicates that administration of 0.9-1.2 mg/kg is an acceptable alternative to succinylcholine for rapid-sequence induction of anesthesia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199311000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 443

Metadata

Authors
Magorian, T., Flannery, K. B., & Miller, R. D.
Venue
Anesthesiology
Published
1993-11-01
Volume
79
Issue
5
Pages
913-918
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2058808925
Cited by
443
References
0
FWCI
16.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Rocuronium, Succinylcholine, and Vecuronium for Rapid-sequence Induction of Anesthesia in Adult Patients. https://app.cochat.ai/papers/10.1097/00000542-199311000-00007
The paper
Magorian, T., Flannery, K. B., & Miller, R. D. (1993). Comparison of Rocuronium, Succinylcholine, and Vecuronium for Rapid-sequence Induction of Anesthesia in Adult Patients. Anesthesiology. https://doi.org/10.1097/00000542-199311000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.