The DOI matches its Crossref record.
Anesthetic and Obstetric Outcome in Morbidly Obese Parturients
Open accessAbstract
BACKGROUND: Large studies reporting anesthetic outcome for morbidly obese parturients are lacking. This study compares the anesthetic and obstetric outcome in morbidly obese parturients and matched control parturients. METHODS: Anesthesia records were prospectively collected for all patients delivering between September 1978 and November 1989 whose weight exceeded 136.4 kg (300 pounds) at the time of delivery. A retrospective control patient group was collected by matching the first patient weighing less than 136.4 kg, delivered in the same month by the same obstertrician, to the corresponding morbidly obese parturient. Anesthetic and obstetric outcome variables were extracted from medical records and analyzed. RESULTS: Sixty-two percent of 117 morbidly obese women underwent cesarean section, while only 24% of control patients delivered abdominally (P < 0.05). Forty-eight percent of all laboring morbidly obese parturients required emergency cesarean section, compared with 9% of control laboring parturients (P < 0.05). Epidural anesthesia was used successfully for labor and cesarean delivery in 74 of 79 morbidly obese women and 66 of 67 control patients. When compared with control patients, initial epidural anesthesia failure was significantly more likely in morbidly obese women, requiring epidural catheter replacement. Difficult tracheal intubation occurred in 6 of 17 morbidly obese women, compared with 0 of 8 control women (P = 0.06). Morbidly obese women had increased incidences of antepartum medical disease, prolonged cesarean section operation times, serious postoperative complications, and increased hospital stays. CONCLUSIONS: The high incidences of antepartum medical disease and emergency cesarean section complicate anesthetic care in the morbidly obese parturients. Epidural anesthesia is feasible; however, the high initial failure rate necessitates early catheter placement, critical block assessment and catheter replacement when indicated, and provision for alternative airway management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Obesity in anaesthesia and intensive care
Adams, J. P., & Murphy, P. G. (2000) · British Journal of Anaesthesia · doi:10.1093/bja/85.1.91 · Cited by 649
Pregnancy: a “teachable moment” for weight control and obesity prevention
Phelan, S. (2010) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2009.06.008 · Cited by 637
Maternal obesity and risk of cesarean delivery: a meta‐analysis
Chu, S. Y., Kim, S. Y., Schmid, C. H., Dietz, P. M., Callaghan, W. M., Lau, J., & Curtis, K. M. (2007) · Obesity Reviews · doi:10.1111/j.1467-789x.2007.00397.x · Cited by 591
Pan, P. H., Bogard, T. D., & Owen, M. D. (2004) · International Journal of Obstetric Anesthesia · doi:10.1016/j.ijoa.2004.04.008 · Cited by 376
Committee Opinion No. 549: Obesity in Pregnancy
(2013) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000425667.10377.60 · Cited by 372
Metadata
- Authors
- Hood, D. D., & Dewan, D. M.
- Venue
- Anesthesiology
- Published
- 1993-12-01
- Volume
- 79
- Issue
- 6
- Pages
- 1210-1218
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1970017487
- Cited by
- 436
- References
- 0
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anesthetic and Obstetric Outcome in Morbidly Obese Parturients. https://app.cochat.ai/papers/10.1097/00000542-199312000-00011
- The paper
- Hood, D. D., & Dewan, D. M. (1993). Anesthetic and Obstetric Outcome in Morbidly Obese Parturients. Anesthesiology. https://doi.org/10.1097/00000542-199312000-00011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.