Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 188

The DOI matches its Crossref record.

Intrathecal Sufentanil Compared to Epidural Bupivacaine for Labor Analgesia

Open access
D'Angelo, Robert, Anderson, Martha T., Philip, Jeffrey, Eisenach, James C. · 1994 · Anesthesiology

Abstract

BACKGROUND: Although intrathecal sufentanil has been reported to provide rapid-onset, complete analgesia lasting 1-3 h for the first stage of labor, no well-controlled double-blind study has compared this technique to the use of epidurally administered local anesthetics. METHODS: Fifty healthy parturient women requesting labor analgesia were studied. In a combined spinal-epidural technique, a spinal needle was inserted through the epidural needle before insertion of the epidural catheter. Patients were randomly assigned to receive either intrathecal sufentanil (10 micrograms) and epidural saline, or intrathecal saline and epidural bupivacaine (30 mg). Visual analog scores for pain, blood pressure, heart rate, sensory levels, and the incidence of nausea, pruritus, and motor blockade were recorded. RESULTS: Patients receiving intrathecal sufentanil had significantly lower visual analog pain scores at 5, 15, and 30 min after injection and a greater duration of analgesia before requesting additional medication (mean 123 vs. 68 min for those receiving bupivacaine; P < 0.05). These patients also experienced pruritus more frequently but motor blockade less frequently than patients receiving epidural bupivacaine. The groups exhibited dermatomal sensory deficits to pin prick as well as bradycardia and hypotension with equal frequency. The length of labor and type of delivery were similar between the groups. No patient experienced a post-dural puncture headache. CONCLUSIONS: The rapid onset of analgesia and lack of motor blockade from intrathecal sufentanil injection may be advantageous in certain clinical situations. With this technique, however, pruritus is common; hypotension may occur; and extensive dermatomal spread suggests that early-onset respiratory depression could occur. Therefore, blood pressure and respiratory adequacy should be monitored if intrathecal sufentanil is used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199406000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 188

Metadata

Authors
D'Angelo, R., Anderson, M. T., Philip, J., & Eisenach, J. C.
Venue
Anesthesiology
Published
1994-06-01
Volume
80
Issue
6
Pages
1209-1215
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2002482162
Cited by
188
References
0
FWCI
15.23
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intrathecal Sufentanil Compared to Epidural Bupivacaine for Labor Analgesia. https://app.cochat.ai/papers/10.1097/00000542-199406000-00007
The paper
D'Angelo, R., Anderson, M. T., Philip, J., & Eisenach, J. C. (1994). Intrathecal Sufentanil Compared to Epidural Bupivacaine for Labor Analgesia. Anesthesiology. https://doi.org/10.1097/00000542-199406000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.