Influence of Phenylephrine Bolus Administration on Left Ventricular Filling Dynamics in Patients with Coronary Artery Disease and Patients with Valvular Aortic Stenosis

Goertz, Axel W., Lindner, Karl H., Schültz, Wolfram, Schirmer, Uwe, Beyer, Michael, Georgieff, Michael · 1994 · Anesthesiology
Cited by 39

The DOI matches its Crossref record.

Abstract

BACKGROUND: Left ventricular diastolic function is known to be impaired in patients with coronary artery disease and patients with valvular aortic stenosis. Phenylephrine is frequently administered as an intravenous bolus in these patients perioperatively to increase coronary perfusion pressure. Although this is common practice, there is no information about the effect of phenylephrine bolus administration on left ventricular filling dynamics. METHODS: Twenty patients with coronary artery disease (group 1), 15 patients with valvular aortic stenosis (group 2), and 10 subjects without cardiovascular disease (group 3, control) entered the study. Left ventricular filling was evaluated using transesophageal pulsed Doppler echocardiography before and after phenylephrine injection given to patients whose mean blood pressure has decreased by more than 20% (and was not higher than 90 mmHg). We recorded the transmitral blood flow velocity curve and measured peak early and peak atrial flow velocity, acceleration and deceleration time of the early flow velocity peak, and mitral valve diameter. We calculated the ratio of peak early to peak atrial flow velocity (PE/PA), acceleration and deceleration rate of the early flow peak, and peak filling rate. RESULTS: Phenylephrine effectively restored arterial pressure in all three groups. However, in group 1, phenylephrine administration resulted in a reduction of PE/PA, acceleration rate of the early flow peak, and peak filling rate from 1.25 (mean) to 0.75 (P < 0.001), 411 to 276 cm/s2 (P < 0.001), and 439 to 305 ml/s (P < 0.001), respectively. In contrast, in group 2, intravenous phenylephrine increased PE/PA, acceleration rate of the early flow peak, and peak filling rate from 0.76 to 0.97 (P < 0.001), 365 to 503 cm/s2 (P < 0.05), and 321 to 388 ml/s (P < 0.01), respectively. In the control subjects, phenylephrine caused a transient reduction of PE/PA and peak filling rate from 1.71 to 1.39 (P < 0.001) and 618 to 524 ml.s-1 (P < 0.001), respectively. CONCLUSIONS: Phenylephrine bolus administration causes an alteration of left ventricular filling in coronary artery disease patients that seems to be more marked than that seen in normal subjects. In patients with aortic stenosis no deleterious effects were observed in response to phenylephrine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199407000-00009

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 39

Metadata

Authors
Goertz, A. W., Lindner, K. H., Schültz, W., Schirmer, U., Beyer, M., & Georgieff, M.
Venue
Anesthesiology
Published
1994-07-01
Volume
81
Issue
1
Pages
49-58
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2083917525
Cited by
39
References
0
FWCI
0.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of Phenylephrine Bolus Administration on Left Ventricular Filling Dynamics in Patients with Coronary Artery Disease and Patients with Valvular Aortic Stenosis. https://app.cochat.ai/papers/10.1097/00000542-199407000-00009
The paper
Goertz, A. W., Lindner, K. H., Schültz, W., Schirmer, U., Beyer, M., & Georgieff, M. (1994). Influence of Phenylephrine Bolus Administration on Left Ventricular Filling Dynamics in Patients with Coronary Artery Disease and Patients with Valvular Aortic Stenosis. Anesthesiology. https://doi.org/10.1097/00000542-199407000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.