Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record.

Reduction by Fentanyl of the Cp50Values of Propofol and Hemodynamic Responses to Various Noxious Stimuli

Kazama, Tomiei, Ikeda, Kazuyuki, Morita, Koji · 1997 · Anesthesiology

Abstract

Background: Propofol and fentanyl infusion rates should be varied according to the patient's responsiveness to stimulation to maintain satisfactory anesthetic and operative conditions. However, somatic and autonomic responses to various noxious stimuli have not been investigated systematically for intravenous propofol and fentanyl anesthesia. Methods: Propofol and fentanyl were administered via computer-assisted continuous infusion to provide stable concentrations and to allow equilibration between plasma-blood and effect-site concentrations. The propofol concentrations needed to suppress eye opening to verbal command and motor responses after 50-Hz electric tetanic stimulation, laryngoscopy, tracheal intubation, and skin incision in 50% or 95% of patients (Cp50 and Cp95) were determined at fentanyl concentrations of 0.0, 1.0, 2.0, 3.0, and 4.0 ng/ml in 133 patients undergoing lower abdominal surgery. The ability of propofol with fentanyl to suppress hemodynamic reactions in response to various noxious stimuli also was evaluated by measuring arterial blood pressure and heart rate before and after stimulation. Results: The various Cp50 values for propofol alone (no fentanyl) for the various stimuli increased in the following order: Cp50loss of consciousness, 4.4 microg/ml (range, 3.8-5.0); Cp50tetanus, 9.3 microg/ml (range, 8.3-10.4); Cp50laryngoscopy, 9.8 microg/ml (range, 8.9-10.8); Cp50skin incision, 10.0 microg/ml (range, 8.1-12.2); and Cp50intubation, 17.4 microg/ml (range, 15.1-20.1; 95% confidence interval). The reduction of Cp50loss of consciousness, with fentanyl was minimal; 11% at 1 ng/ml of fentanyl and 17% at 3 ng/ml of fentanyl. A plasma fentanyl concentration of 1 ng/ml (3 ng/ml) resulted in a 31-34% (50-55%) reduction of the propofol Cp50s for tetanus, laryngoscopy, intubation, and skin incision. Propofol alone depresses prestimulation blood pressure but had no influence on the magnitude blood pressure or heart rate increase to stimulation. Propofol used with fentanyl attenuated the systolic blood pressure increases to various noxious stimuli in a dose-dependent fashion. Conclusions: The authors successfully defined the propofol concentration required for various stimuli. Tracheal intubation was the strongest stimulus. The absence of somatic reactions for propofol does not guarantee hemodynamic stability without fentanyl. Propofol with fentanyl was able to suppress motor and hemodynamic reactions to various noxious stimuli.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199708000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 206

Metadata

Authors
Kazama, T., Ikeda, K., & Morita, K.
Venue
Anesthesiology
Published
1997-08-01
Volume
87
Issue
2
Pages
213-227
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2072945503
Cited by
206
References
0
FWCI
10.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction by Fentanyl of the Cp50Values of Propofol and Hemodynamic Responses to Various Noxious Stimuli. https://app.cochat.ai/papers/10.1097/00000542-199708000-00007
The paper
Kazama, T., Ikeda, K., & Morita, K. (1997). Reduction by Fentanyl of the Cp50Values of Propofol and Hemodynamic Responses to Various Noxious Stimuli. Anesthesiology. https://doi.org/10.1097/00000542-199708000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.