Effects of Small Concentrations of Volatile Anesthetics on Action Potential Firing of Neocortical Neurons In Vitro
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Background: Volatile general anesthetics depress neuronal activity in the mammalian central nervous system and enhance inhibitory Cl- currents flowing across the gamma-aminobutyric acid A (GABA(A)) receptor-ion channel complex. The extent to which an increase in GABA(A)-mediated synaptic inhibition contributes to the decrease in neuronal firing must be determined, because many further effects of these agents have been reported on the molecular level. Methods: The actions of halothane, isoflurane, and enflurane on the firing patterns of single neurons were investigated by extracellular recordings in organotypic slice cultures derived from the rat neocortex. Results: Volatile anesthetics depressed spontaneous action potential firing of neocortical neurons in a concentration-dependent manner. The estimated median effective concentration (EC50) values were about one half the EC50 values for general anesthesia. In the presence of the GABA(A) antagonist bicuculline (20 microM), the effectiveness of halothane, isoflurane, and enflurane in reducing the discharge rates were diminished by 48-65%, indicating that these drugs act via the GABA(A) receptor. Conclusions: Together with recent investigations, our results provide evidence that halothane, isoflurane, and enflurane reduced spontaneous action potential firing of neocortical neurons in cultured brain slices mainly by increasing GABA(A)-mediated synaptic inhibition. At concentrations, approximately one half the EC50 for general anesthesia, volatile anesthetics increased overall GABA(A)-mediated synaptic inhibition about twofold, thus decreasing spontaneous action potential firing by half.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whittington, M. A., Traub, R. D., & Jefferys, J. G. R. (1995) · Nature · doi:10.1038/373612a0 · Cited by 1,613
Perouansky, M., Baranov, D., Salman, M., & Yaari, Y. (1995) · Anesthesiology · doi:10.1097/00000542-199507000-00014 · Cited by 104
Cited by
Jurd, R., Arrasa, M., Lambert, S., Drexler, B., Siegwart, R., Crestani, F., Zaugg, M., Vogt, K. E., Ledermann, B., Antkowiak, B., et al. (2003) · The FASEB Journal · doi:10.1096/fj.02-0611fje · Cited by 558
Self-citationNeuroreceptors and Ion Channels as the Basis for Drug Action: Past, Present, and Future
Narahashi, T. (2000) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)39034-2 · Cited by 257
Soft and MRI Compatible Neural Electrodes from Carbon Nanotube Fibers
Lu, L., Fu, X., Liew, Y., Zhang, Y., Zhao, S., Xu, Z., Zhao, J., Li, D., Li, Q., Stanley, G. B., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b04456 · Cited by 146
Transformations of Electrosensory Encoding Associated with an Adaptive Filter
Sawtell, N. B., & Williams, A. (2008) · The Journal of Neuroscience · doi:10.1523/jneurosci.4946-07.2008 · Cited by 61
Metadata
- Authors
- Antkowiak, B., & Helfrich-Forster, C.
- Venue
- Anesthesiology
- Published
- 1998-06-01
- Volume
- 88
- Issue
- 6
- Pages
- 1592-1605
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1993631293
- Cited by
- 53
- References
- 2
- FWCI
- 1.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of Small Concentrations of Volatile Anesthetics on Action Potential Firing of Neocortical Neurons In Vitro. https://app.cochat.ai/papers/10.1097/00000542-199806000-00024
- The paper
- Antkowiak, B., & Helfrich-Forster, C. (1998). Effects of Small Concentrations of Volatile Anesthetics on Action Potential Firing of Neocortical Neurons In Vitro. Anesthesiology. https://doi.org/10.1097/00000542-199806000-00024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.