The DOI matches its Crossref record.
Multicenter Randomized Comparison of the Efficacy and Safety of Xenon and Isoflurane in Patients Undergoing Elective Surgery
Open accessAbstract
Background: All general anesthetics used are known to have a negative inotropic side effect. Since xenon does not have a negative inotropic effect, it could be an interesting future general anesthetic. The aim of this clinical multicenter trial was to test the hypothesis of whether recovery after xenon anesthesia is faster compared with an accepted, standardized anesthetic regimen and that it is as effective and safe. Method: A total of 224 patients in six centers were included in the protocol. They were randomly assigned to receive either xenon (60 +/- 5%) in oxygen or isoflurane (end-tidal concentration, 0.5%) combined with nitrous oxide (60 +/- 5%). Sufentanil (10 mcirog) was intravenously injected if indicated by defined criteria. Hemodynamic, respiratory, and recovery parameters, the amount of sufentanil, and side effects were assessed. Results: The recovery parameters demonstrated a statistically significant faster recovery from xenon anesthesia when compared with isoflurane-nitrous oxide. The additional amount of sufentanil did not differ between both anesthesia regimens. Hemodynamics and respiratory parameters remained stable throughout administration of both anesthesia regimens, with advantages for the xenon group. Side effects occurred to the same extent with xenon in oxygen and isoflurane-nitrous oxide. Conclusion: This first randomized controlled multicenter trial on the use of xenon as an inhalational anesthetic confirms, in a large group of patients, that xenon in oxygen provides effective and safe anesthesia, with the advantage of a more rapid recovery when compared with anesthesia using isoflurane-nitrous oxide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Xenon Mitigates Isoflurane-induced Neuronal Apoptosis in the Developing Rodent Brain
Ma, D., Williamson, P., Januszewski, A., Nogaro, M.-C., Hossain, M., Ong, L. P., Shu, Y., Franks, N. P., & Maze, M. (2007) · Anesthesiology · doi:10.1097/01.anes.0000264762.48920.80 · Cited by 279
Xenon and hypothermia combine to provide neuroprotection from neonatal asphyxia
Ma, D., Hossain, M., Chow, A., Arshad, M., Battson, R. M., Sanders, R. D., Mehmet, H., Edwards, A. D., Franks, N. P., & Maze, M. (2005) · Annals of Neurology · doi:10.1002/ana.20547 · Cited by 276
Haseneder, R., Kratzer, S., Kochs, E., Eckle, V.-S., Zieglgänsberger, W., & Rammes, G. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31818d6aee · Cited by 47
Kratzer, S., Mattusch, C., Kochs, E., Eder, M., Haseneder, R., & Rammes, G. (2012) · Anesthesiology · doi:10.1097/aln.0b013e3182475d66 · Cited by 21
Metadata
- Authors
- Rossaint, R., Reyle-Hahn, M., Schulte am Esch, J., Scholz, J., Scherpereel, P., Vallet, B., Giunta, F., Del Turco, M., Erdmann, W., Tenbrinck, R., Hammerle, A. F., & Nagele, P.
- Venue
- Anesthesiology
- Published
- 2003-01-01
- Volume
- 98
- Issue
- 1
- Pages
- 6-13
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2010482008
- Cited by
- 219
- References
- 0
- FWCI
- 19.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multicenter Randomized Comparison of the Efficacy and Safety of Xenon and Isoflurane in Patients Undergoing Elective Surgery. https://app.cochat.ai/papers/10.1097/00000542-200301000-00005
- The paper
- Rossaint, R., Reyle-Hahn, M., Schulte am Esch, J., Scholz, J., Scherpereel, P., Vallet, B., Giunta, F., Del Turco, M., Erdmann, W., Tenbrinck, R., Hammerle, A. F., & Nagele, P. (2003). Multicenter Randomized Comparison of the Efficacy and Safety of Xenon and Isoflurane in Patients Undergoing Elective Surgery. Anesthesiology. https://doi.org/10.1097/00000542-200301000-00005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.