Cricoid Pressure Displaces the Esophagus: An Observational Study Using Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record.
Abstract
Background: Cricoid pressure (CP) is often used during general anesthesia induction to prevent passive regurgitation of gastric contents. The authors used magnetic resonance imaging to determine the anatomic relationship between the esophagus and the cricoid cartilage ("cricoid") with and without CP. Methods: Magnetic resonance images of the necks of 22 healthy volunteers were reviewed with and without CP. Esophageal and airway dimensions, distance between the midline of the vertebral body and the midline of the esophagus, and distance between the lateral border of the cricoid or vertebral body and the lateral border of the esophagus were measured. Results: The esophagus was displaced laterally relative to the cricoid in 52.6% of necks without CP and 90.5% with CP. CP shifted the esophagus relative to its initial position to the left in 68.4% of subjects and to the right in 21.1% of subjects. Unopposed esophagus was seen in 47.4% of necks without CP and 71.4% with CP. Lateral laryngeal displacement and airway compression were demonstrated in 66.7% and 81.0% of necks, respectively, as a result of CP. Conclusion: In the absence of CP, the esophagus was lateral to the cricoid in more than 50% of the sample. CP further displaced both the esophagus and the larynx laterally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Preoxygenation and prevention of desaturation during emergency airway management
Weingart, S. D., & Levitan, R. M. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.10.002 · Cited by 554
“Computed tomography and magnetic resonance imaging scanning have shown that cricoid pressure causes lateral displacement of the esophagus in more than 90% of patients and laryngeal/tracheal compression in 80%.(87,88) Numerous ventilation studies have found that cricoid pressure hinders bagvalve-mask device ventilation…”
BackgroundThe difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Sakai, T., Planinsic, R. M., Quinlan, J. J., Handley, L. J., Kim, T.-Y., & Hilmi, I. A. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000237296.57941.e7 · Cited by 196
““Proper” cricoid pressure application is often difficult in terms of the force needed to occlude the upper portion of the esophagus because of the anatomical alignment of the larynx and the esophagus ( 7 ).”
BackgroundLipman, S., Cohen, S., Einav, S., Jeejeebhoy, F., Mhyre, J. M., Morrison, L. J., Katz, V., Tsen, L. C., Daniels, K., Halamek, L. P., et al. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000171 · Cited by 190
Metadata
- Authors
- Smith, K. J., Dobranowski, J., Yip, G., Dauphin, A., & Choi, P. T.-L.
- Venue
- Anesthesiology
- Published
- 2003-07-01
- Volume
- 99
- Issue
- 1
- Pages
- 60-64
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2119612388
- Cited by
- 219
- References
- 0
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cricoid Pressure Displaces the Esophagus: An Observational Study Using Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1097/00000542-200307000-00013
- The paper
- Smith, K. J., Dobranowski, J., Yip, G., Dauphin, A., & Choi, P. T.-L. (2003). Cricoid Pressure Displaces the Esophagus: An Observational Study Using Magnetic Resonance Imaging. Anesthesiology. https://doi.org/10.1097/00000542-200307000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.