CoChat

Cricoid Pressure Displaces the Esophagus: An Observational Study Using Magnetic Resonance Imaging

Open access
Smith, Kevin J., Dobranowski, Julian, Yip, Gordon, Dauphin, Alezandre, Choi, Peter T-L. · 2003 · Anesthesiology
Cited by 219

The DOI matches its Crossref record.

Abstract

Background: Cricoid pressure (CP) is often used during general anesthesia induction to prevent passive regurgitation of gastric contents. The authors used magnetic resonance imaging to determine the anatomic relationship between the esophagus and the cricoid cartilage ("cricoid") with and without CP. Methods: Magnetic resonance images of the necks of 22 healthy volunteers were reviewed with and without CP. Esophageal and airway dimensions, distance between the midline of the vertebral body and the midline of the esophagus, and distance between the lateral border of the cricoid or vertebral body and the lateral border of the esophagus were measured. Results: The esophagus was displaced laterally relative to the cricoid in 52.6% of necks without CP and 90.5% with CP. CP shifted the esophagus relative to its initial position to the left in 68.4% of subjects and to the right in 21.1% of subjects. Unopposed esophagus was seen in 47.4% of necks without CP and 71.4% with CP. Lateral laryngeal displacement and airway compression were demonstrated in 66.7% and 81.0% of necks, respectively, as a result of CP. Conclusion: In the absence of CP, the esophagus was lateral to the cricoid in more than 50% of the sample. CP further displaced both the esophagus and the larynx laterally.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200307000-00013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 219

Metadata

Authors
Smith, K. J., Dobranowski, J., Yip, G., Dauphin, A., & Choi, P. T.-L.
Venue
Anesthesiology
Published
2003-07-01
Volume
99
Issue
1
Pages
60-64
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2119612388
Cited by
219
References
0
FWCI
5.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cricoid Pressure Displaces the Esophagus: An Observational Study Using Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1097/00000542-200307000-00013
The paper
Smith, K. J., Dobranowski, J., Yip, G., Dauphin, A., & Choi, P. T.-L. (2003). Cricoid Pressure Displaces the Esophagus: An Observational Study Using Magnetic Resonance Imaging. Anesthesiology. https://doi.org/10.1097/00000542-200307000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.