Short- and Long-term Prognostic Value of Postoperative Cardiac Troponin I Concentration in Patients Undergoing Coronary Artery Bypass Grafting

Open access
Fellahi, Jean-Luc, Gué, Xavier, Richomme, Xavier, Monier, Emmanuel, Guillou, Louis, Riou, Bruno · 2003 · Anesthesiology

Abstract

Background: The value of postoperative cardiac troponin I (cTnI) has been shown to indicate a higher risk of in-hospital death after cardiac surgery. The authors therefore assessed the long-term prognostic value of cTnI in patients undergoing elective coronary artery bypass grafting. Methods: Consecutive patients (n = 202) were included and divided into two groups according to the postoperative value of cTnI (< or >/= 13 ng/ml). In-hospital mortality and nonfatal cardiac events (delayed extubation > 24 h; postoperative requirement of inotropic agent; ventricular and supraventricular arrhythmia; postoperative myocardial infarction) were recorded. Survivors were then followed up over a 2-yr period. Data are median and odds ratio (95% confidence interval). Results: Of all patients, 174 (86%) had a low cTnI (4.1 ng/ml; range, 1.1-12.6) and 28 (14%) had a high cTnI (23.8 ng/ml; range, 13.4-174.6). In-hospital mortality was not significantly different (4 vs. 2%), whereas long-term mortality (18 vs. 3%, P = 0.006) and mortality from cardiac cause (18 vs. 1%, P < 0.001) was greater in patients with a high cTnI. A high cTnI was a significant factor predicting death (odds ratio, 7.3 [2.0-27.1]) or death from cardiac causes (odds ratio, 37.4 [4.2-334.4]). Nonfatal cardiac events were also more frequent in the hospital (64 vs. 41%, P = 0.02) and within the 2-yr follow-up period (39% vs. 16%, P = 0.03) in patients with high cTnI. Conclusion: A high postoperative peak of cTnI is associated with increased risk of death, death from cardiac causes, and nonfatal cardiac events within 2 yr after coronary artery bypass grafting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200308000-00007

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 176

Metadata

Authors
Fellahi, J.-L., Gué, X., Richomme, X., Monier, E., Guillou, L., & Riou, B.
Venue
Anesthesiology
Published
2003-08-01
Volume
99
Issue
2
Pages
270-274
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2086187895
Cited by
176
References
1
FWCI
12.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Short- and Long-term Prognostic Value of Postoperative Cardiac Troponin I Concentration in Patients Undergoing Coronary Artery Bypass Grafting. https://app.cochat.ai/papers/10.1097/00000542-200308000-00007
The paper
Fellahi, J.-L., Gué, X., Richomme, X., Monier, E., Guillou, L., & Riou, B. (2003). Short- and Long-term Prognostic Value of Postoperative Cardiac Troponin I Concentration in Patients Undergoing Coronary Artery Bypass Grafting. Anesthesiology. https://doi.org/10.1097/00000542-200308000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.