Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 244

The DOI matches its Crossref record.

Injuries and Liability Related to Central Vascular Catheters: A Closed Claims Analysis

Open access
Domino, Karen B., Bowdle, T. Andrew, Posner, Karen L., Spitellie, Pete H., Lee, Lorri A., Cheney, Frederick W. · 2004 · Anesthesiology

Abstract

Background: To assess changing patterns of injury and liability associated with central venous or pulmonary artery catheters, the authors analyzed closed malpractice claims for central catheter injuries in the American Society of Anesthesiologists Closed Claims database. Methods: All claims for which a central catheter (i.e., central venous or pulmonary artery catheter) was the primary damaging event for the injury were compared with the rest of the claims in the database. Central catheter complications were defined as being related to vascular access or catheter use or maintenance. Statistical analysis was performed using the chi-square test, Fisher exact test, or Z test (proportions) and the Kolmogorov-Smirnov test (payments). Results: The database included 110 claims for injuries related to central catheters (1.7% of 6,449 claims). Claims for central catheter injuries had a higher severity of injury, with an increased proportion of death (47%) compared with other claims in the database (29%, P < 0.01). The most common complications were wire/catheter embolus (n = 20), cardiac tamponade (n = 16), carotid artery puncture/cannulation (n =16), hemothorax (n =15), and pneumothorax (n =14). Cardiac tamponade, hemothorax, and pulmonary artery rupture had a higher proportion of death (P < 0.05) compared with the rest of the central catheter injures. The proportion of claims for vascular access injury increased (47% to 84%) and use/maintenance injury decreased (53% to 16%) in 1994-1999 compared with 1978-1983 (P < 0.05). Conclusions: Claims related to central catheters had a high severity of patient injury. The most common complications causing injury were wire/catheter embolus, cardiac tamponade, carotid artery puncture/cannulation, hemothorax, and pneumothorax.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200406000-00013

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 244

Metadata

Authors
Domino, K. B., Bowdle, T. A., Posner, K. L., Spitellie, P. H., Lee, L. A., & Cheney, F. W.
Venue
Anesthesiology
Published
2004-06-01
Volume
100
Issue
6
Pages
1411-1418
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1985152184
Cited by
244
References
0
FWCI
38.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Injuries and Liability Related to Central Vascular Catheters: A Closed Claims Analysis. https://app.cochat.ai/papers/10.1097/00000542-200406000-00013
The paper
Domino, K. B., Bowdle, T. A., Posner, K. L., Spitellie, P. H., Lee, L. A., & Cheney, F. W. (2004). Injuries and Liability Related to Central Vascular Catheters: A Closed Claims Analysis. Anesthesiology. https://doi.org/10.1097/00000542-200406000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.