CoChat

Continuous, Noninvasive, and Localized Microvascular Tissue Oximetry Using Visible Light Spectroscopy

Open access
Benaron, David A., Parachikov, Ilian H., Friedland, Shai, Soetikno, Roy, Brock-Utne, John, van der Starre, Peter J. A., Nezhat, Camran, Terris, Martha K., Maxim, Peter G., Carson, Jeffrey J. L., Razavi, Mahmood K., Gladstone, Hayes B., Fincher, Edgar F., Hsu, Christopher P., Clark, F. Landon, Cheong, Wai-Fung, Duckworth, Joshua L., Stevenson, David K. · 2004 · Anesthesiology
Cited by 98

The DOI matches its Crossref record.

Abstract

Background: The authors evaluated the ability of visible light spectroscopy (VLS) oximetry to detect hypoxemia and ischemia in human and animal subjects. Unlike near-infrared spectroscopy or pulse oximetry (SpO2), VLS tissue oximetry uses shallow-penetrating visible light to measure microvascular hemoglobin oxygen saturation (StO2) in small, thin tissue volumes. Methods: In pigs, StO2 was measured in muscle and enteric mucosa during normoxia, hypoxemia (SpO2 = 40-96%), and ischemia (occlusion, arrest). In patients, StO2 was measured in skin, muscle, and oral/enteric mucosa during normoxia, hypoxemia (SpO2 = 60-99%), and ischemia (occlusion, compression, ventricular fibrillation). Results: In pigs, normoxic StO2 was 71 +/- 4% (mean +/- SD), without differences between sites, and decreased during hypoxemia (muscle, 11 +/- 6%; P < 0.001) and ischemia (colon, 31 +/- 11%; P < 0.001). In patients, mean normoxic StO2 ranged from 68 to 77% at different sites (733 measures, 111 subjects); for each noninvasive site except skin, variance between subjects was low (e.g., colon, 69% +/- 4%, 40 subjects; buccal, 77% +/- 3%, 21 subjects). During hypoxemia, StO2 correlated with SpO2 (animals, r2 = 0.98; humans, r2 = 0.87). During ischemia, StO2 initially decreased at -1.3 +/- 0.2%/s and decreased to zero in 3-9 min (r2 = 0.94). Ischemia was distinguished from normoxia and hypoxemia by a widened pulse/VLS saturation difference (Delta < 30% during normoxia or hypoxemia vs. Delta > 35% during ischemia). Conclusions: VLS oximetry provides a continuous, noninvasive, and localized measurement of the StO2, sensitive to hypoxemia, regional, and global ischemia. The reproducible and narrow StO2 normal range for oral/enteric mucosa supports use of this site as an accessible and reliable reference point for the VLS monitoring of systemic flow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200406000-00019

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 98

Metadata

Authors
Benaron, D. A., Parachikov, I. H., Friedland, S., Soetikno, R., Brock-Utne, J., van der Starre, P. J. A., Nezhat, C., Terris, M. K., Maxim, P. G., Carson, J. J. L., Razavi, M. K., Gladstone, H. B., Fincher, E. F., Hsu, C. P., Clark, F. L., Cheong, W.-F., Duckworth, J. L., & Stevenson, D. K.
Venue
Anesthesiology
Published
2004-06-01
Volume
100
Issue
6
Pages
1469-1475
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2126159680
Cited by
98
References
0
FWCI
3.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous, Noninvasive, and Localized Microvascular Tissue Oximetry Using Visible Light Spectroscopy. https://app.cochat.ai/papers/10.1097/00000542-200406000-00019
The paper
Benaron, D. A., Parachikov, I. H., Friedland, S., Soetikno, R., Brock-Utne, J., van der Starre, P. J. A., Nezhat, C., Terris, M. K., Maxim, P. G., Carson, J. J. L., Razavi, M. K., Gladstone, H. B., Fincher, E. F., Hsu, C. P., Clark, F. L., Cheong, W.-F., Duckworth, J. L., & Stevenson, D. K. (2004). Continuous, Noninvasive, and Localized Microvascular Tissue Oximetry Using Visible Light Spectroscopy. Anesthesiology. https://doi.org/10.1097/00000542-200406000-00019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.