CoChat

Deliberate Perioperative Systems Design Improves Operating Room Throughput

Open access
Sandberg, Warren S., Daily, Bethany, Egan, Marie, Stahl, James E., Goldman, Julian M., Wiklund, Richard A., Rattner, David · 2005 · Anesthesiology
Cited by 214

The DOI matches its Crossref record.

Abstract

Background: New operating room (OR) design focuses more on the surgical environment than on the process of care. The authors sought to improve OR throughput and reduce time per case by goal-directed design of a demonstration OR and the perioperative processes occurring within and around it. Methods: The authors constructed a three-room suite including an OR, an induction room, and an early recovery area. Traditionally sequential activities were run in parallel, and nonsurgical activities were moved from the OR to the supporting spaces. The new workflow was supported by additional anesthesia and nursing personnel. The authors used a retrospective, case- and surgeon-matched design to compare the throughput, cost, and revenue performance of the new OR to traditional ORs. Results: For surgeons performing the same case mix in both environments, the new OR processed more cases per day than traditional ORs and used less time per case. Throughput improvement came from superior nonoperative performance. Nonoperative Time was reduced from 67 min (95% confidence interval, 64-70 min) to 38 min (95% confidence interval, 35-40 min) in the new OR. All components of Nonoperative Time were meaningfully reduced. Operative Time decreased by approximately 5%. Hospital and anesthesia costs per case increased, but the increased throughput offset costs and the global net margin was unchanged. Conclusions: Deliberate OR and perioperative process redesign improved throughput. Performance improvement derived from relocating and reorganizing nonoperative activities. Better OR throughput entailed additional costs but allowed additional patients to be accommodated in the OR while generating revenue that balanced these additional costs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200508000-00025

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 214

Metadata

Authors
Sandberg, W. S., Daily, B., Egan, M., Stahl, J. E., Goldman, J. M., Wiklund, R. A., & Rattner, D.
Venue
Anesthesiology
Published
2005-08-01
Volume
103
Issue
2
Pages
406-418
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2170488310
Cited by
214
References
0
FWCI
27.26
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deliberate Perioperative Systems Design Improves Operating Room Throughput. https://app.cochat.ai/papers/10.1097/00000542-200508000-00025
The paper
Sandberg, W. S., Daily, B., Egan, M., Stahl, J. E., Goldman, J. M., Wiklund, R. A., & Rattner, D. (2005). Deliberate Perioperative Systems Design Improves Operating Room Throughput. Anesthesiology. https://doi.org/10.1097/00000542-200508000-00025

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.