Practice Advisory for Intraoperative Awareness and Brain Function Monitoring: A Report by the American Society of Anesthesiologists Task Force on Intraoperative Awareness
Open accessAbstract
PRACTICE advisories are systematically developed reports that are intended to assist decision making in areas of patient care. Advisories provide a synthesis and analysis of expert opinion, clinical feasibility data, open forum commentary, and consensus surveys. Advisories are not intended as standards, guidelines, or absolute requirements. They may be adopted, modified, or rejected according to clinical needs and constraints.The use of practice advisories cannot guarantee any specific outcome. Practice advisories summarize the state of the literature and report opinions derived from a synthesis of task force members, expert consultants, open forums, and public commentary. Practice advisories are not supported by scientific literature to the same degree as are standards or guidelines because sufficient numbers of adequately controlled studies are lacking. Practice advisories are subject to periodic revision as warranted by the evolution of medical knowledge, technology, and practice.Intraoperative awareness under general anesthesia is a rare occurrence, with a reported incidence of 0.1–0.2%.1–4Significant psychological sequelae (e.g. , post–traumatic stress disorder) may occur after an episode of intraoperative awareness, and affected patients may remain severely disabled for extended periods of time.5However, in some circumstances, intraoperative awareness may be unavoidable to achieve other critically important anesthetic goals.The following terms or concepts discussed in this Advisory include: consciousness, general anesthesia, depth of anesthesia or depth of hypnosis, recall, amnesia, intraoperative awareness, and brain function monitors. Consistent definitions for these terms are not available in the literature. For purposes of this Advisory, these terms are operationally defined or identified as follows:Consciousness is a state in which a patient is able to process information from his or her surroundings. Consciousness is assessed by observing a patient’s purposeful responses to various stimuli. Identifiers of purposeful responses include organized movements following voice commands or noxious/painful stimuli.*For example, opening of the eyes is one of several possible identifiers or markers of consciousness. Purposeful responses may be absent when paralysis is present as a consequence of neurologic disease or the administration of a neuromuscular blocking drug.General anesthesia is defined as a drug-induced loss of consciousness during which patients are not arousable, even by painful stimulation.†The ability to maintain ventilatory function independently is often impaired. Patients often require assistance in maintaining a patent airway, and positive-pressure ventilation may be required because of depressed spontaneous ventilation or drug-induced depression of neuromuscular function. Cardiovascular function may be impaired.Depth of anesthesia or depth of hypnosis refers to a continuum of progressive central nervous system depression and decreased responsiveness to stimulation.For the purpose of this Advisory, recall is the patient’s ability to retrieve stored memories. Recall is assessed by a patient’s report of previous events, in particular, events that occurred during general anesthesia. Explicit memory is assessed by the patient’s ability to recall specific events that took place during general anesthesia. Implicit memory is assessed by changes in performance or behavior without the ability to recall specific events that took place during general anesthesia that led to those changes.6A report of recall may be spontaneous or it may only be elicited in a structured interview or questionnaire. This Advisory does not address implicit memory.Amnesia is the absence of recall. Many anesthetic drugs produce amnesia at concentrations well below those necessary for suppression of consciousness. Anterograde amnesia is intended when a drug with amnestic properties is administered before induction of anesthesia. Retrograde amnesia is intended when a drug such as a benzodiazepine is administered after an event that may have caused or been associated with intraoperative consciousness in the hope that it will suppress memory formation and “rescue” from recall.Intraoperative awareness occurs when a patient becomes conscious during a procedure performed under general anesthesia and subsequently has recall of these events. For the purpose of this Advisory, recall is limited to explicit memory and does not include the time before general anesthesia is fully induced or the time of emergence from general anesthesia, when arousal and return of consciousness are intended. Dreaming is not considered intraoperative awareness.Brain function monitors are devices that record or process brain electrical activity and convert these signals mathematically into a continuous measure typically scaled from 0 to 100. In addition to monitoring spontaneous cortical electrical activity (electroencephalogram [EEG]), these devices may a
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alkire, M. T., Hudetz, A. G., & Tononi, G. (2008) · Science · doi:10.1126/science.1149213 · Cited by 1,245
Anesthesia Awareness and the Bispectral Index
Avidan, M. S., Zhang, L., Burnside, B. A., Finkel, K. J., Searleman, A. C., Selvidge, J. A., Saager, L., Turner, M. S., Rao, S., Bottros, M., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0707361 · Cited by 975
Electroencephalogram signatures of loss and recovery of consciousness from propofol
Purdon, P. L., Pierce, E. T., Mukamel, E. A., Prerau, M. J., Walsh, J. L., Wong, K. F. K., Salazar-Gomez, A. F., Harrell, P. G., Sampson, A. L., Cimenser, A., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1221180110 · Cited by 854
Prevention of Intraoperative Awareness in a High-Risk Surgical Population
Avidan, M. S., Jacobsohn, E., Glick, D., Burnside, B. A., Zhang, L., Villafranca, A., Karl, L., Kamal, S., Torres, B., O'Connor, M., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1100403 · Cited by 581
Checketts, M. R., Alladi, R., Ferguson, K., Gemmell, L., Handy, J. M., Klein, A. A., Love, N. J., Misra, U., Morris, C., Nathanson, M. H., et al. (2016) · Anaesthesia · doi:10.1111/anae.13316 · Cited by 490
Metadata
- Venue
- Anesthesiology
- Published
- 2006-04-01
- Volume
- 104
- Issue
- 4
- Pages
- 847-864
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W4211048527
- Cited by
- 294
- References
- 0
- FWCI
- 19.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Practice Advisory for Intraoperative Awareness and Brain Function Monitoring: A Report by the American Society of Anesthesiologists Task Force on Intraoperative Awareness. https://app.cochat.ai/papers/10.1097/00000542-200604000-00031
- The paper
- Practice Advisory for Intraoperative Awareness and Brain Function Monitoring: A Report by the American Society of Anesthesiologists Task Force on Intraoperative Awareness. (2006). Anesthesiology. https://doi.org/10.1097/00000542-200604000-00031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.