Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record.

Contrasting Effects of Colloid and Crystalloid Resuscitation Fluids on Cardiac Vascular Permeability

Jacob, Matthias, Bruegger, Dirk, Rehm, Markus, Welsch, Ulrich, Conzen, Peter, Becker, Bernhard F. · 2006 · Anesthesiology

Abstract

Background: Fluid extravasation may lead to myocardial edema and consequent reduction in ventricular function. Albumin is presumed to interact with the endothelial glycocalyx. The authors' objective was to compare the impact of different resuscitation fluids (human albumin, hydroxyethyl starch, saline) on vascular integrity. Methods: In an isolated perfused heart model (guinea pig), Krebs-Henseleit buffer was augmented with colloids (one third volume 5% albumin or 6% hydroxyethyl starch 130/0.4) or crystalloid (0.9% saline). Perfusion pressure and vascular fluid filtration (epicardial transudate formation) were assessed at different flow rates. After global, stopped-flow ischemia (37 degrees C, 20 min), hearts were reperfused with the same resuscitation fluid additives. In a second series, the authors applied the respective perfusates after enzymatic digestion of the endothelial glycocalyx (heparinase, 10 U over 15 min). Results: Both 5% albumin and 6% hydroxyethyl starch decreased fluid extravasation versus saline (68.4 +/- 5.9, 134.8 +/- 20.5, and 436.8 +/- 14.7 microl/min, respectively, at 60 cm H(2)O perfusion pressure; P < 0.05), the corresponding colloid osmotic pressures being 2.95, 5.45, and 0.00 mmHg. Digestion of the endothelial glycocalyx decreased coronary integrity in both colloid groups. After ischemia, a transient increase in vascular leak occurred with Krebs-Henseleit buffer containing hydroxyethyl starch and saline, but not with albumin. The authors observed no difference between intravascular and bulk interstitial colloid concentration in the steady state. Notwithstanding, electron microscopy revealed an intact endothelial glycocalyx and no interstitial edema in the albumin group. Conclusion: Ex vivo, albumin more effectively prevented fluid extravasation in the heart than crystalloid or artificial colloid. This effect was partly independent of colloid osmotic pressure and may be attributable to an interaction of albumin with the endothelial glycocalyx.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200606000-00018

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 210

Metadata

Authors
Jacob, M., Bruegger, D., Rehm, M., Welsch, U., Conzen, P., & Becker, B. F.
Venue
Anesthesiology
Published
2006-06-01
Volume
104
Issue
6
Pages
1223-1231
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2018586741
Cited by
210
References
0
FWCI
8.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Contrasting Effects of Colloid and Crystalloid Resuscitation Fluids on Cardiac Vascular Permeability. https://app.cochat.ai/papers/10.1097/00000542-200606000-00018
The paper
Jacob, M., Bruegger, D., Rehm, M., Welsch, U., Conzen, P., & Becker, B. F. (2006). Contrasting Effects of Colloid and Crystalloid Resuscitation Fluids on Cardiac Vascular Permeability. Anesthesiology. https://doi.org/10.1097/00000542-200606000-00018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.