Cerebrospinal Fluid and Spinal Cord Distribution of Baclofen and Bupivacaine during Slow Intrathecal Infusion in Pigs
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: Increasing numbers of patients are receiving chronic intrathecal infusions of local anesthetics, baclofen, opioids, and other analgesics via implanted pumps. These infusions typically deliver drugs at rates measured in microliters per hour. However, to date, there have been no studies aimed at characterizing drug distribution within cerebrospinal fluid (CSF) and spinal cord during these slow infusion rates. Therefore, this study was designed to address this knowledge gap. Methods: Anesthetized pigs were instrumented with eight intrathecal microdialysis probes placed at multiple points along the neuroaxis in both the anterior and posterior intrathecal space to permit continuous CSF sampling for measurement of bupivacaine and baclofen concentrations. Animals were divided into three groups and received bupivacaine and baclofen infusions at 20 or 1,000 microl/h or as a 1,000-microl bolus over 5 min every hour. Drug administration continued for 8 h, at which time the animals were killed, and the spinal cord was removed and divided into 1-cm-long sections that were further divided into anterior and posterior portions for measurement of bupivacaine and baclofen concentrations. Results: In all groups, drug concentration in CSF and spinal cord decreased rapidly as a function of distance from the site of administration, with most drug found within a few centimeters. In addition, there were significant anterior-posterior differences in both CSF and spinal cord drug concentrations. Conclusions: During slow intrathecal infusion, drug distribution in CSF and spinal cord is severely limited in all groups, although significantly more so in the 20-microl/h infusion group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Blockade in Clinical Anesthesia and Management of Pain
Cousins, M. J., Bridenbaugh, P. O., & Lippincott, P. J. B. (1981) · Anesthesiology · doi:10.1097/00000542-198110000-00046 · Cited by 824
Ummenhofer, W. C., Arends, R. H., Shen, D. D., & Bernards, C. M. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00018 · Cited by 316
Self-citationBalédent, O., Gondry-Jouet, C., Meyer, M.-E., De Marco, G., Le Gars, D., Henry-Feugeas, M.-C., & Idy-Peretti, I. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000100892.87214.49 · Cited by 195
Bernards, C. M., Shen, D. D., Sterling, E. S., Adkins, J. E., Risler, L. J., Phillips, B., & Ummenhofer, W. C. (2003) · Anesthesiology · doi:10.1097/00000542-200308000-00029 · Cited by 145
Self-citationChronically Infused Intrathecal Morphine in Dogs
Yaksh, T. L., Horais, K. A., Tozier, N. A., Allen, J. W., Rathbun, M. L., Rossi, S. S., Sommer, C., Meschter, C. L., Richter, P. J., & Hildebrand, K. R. (2003) · Anesthesiology · doi:10.1097/00000542-200307000-00028 · Cited by 138 · cited 1×
“eter, and animal studies demonstrate that they are related to the concentration of morphine infused.(32,33)”
BackgroundBhadelia, R. A., Bogdan, A. R., Kaplan, R. F., & Wolpert, S. M. (1997) · Neuroradiology · doi:10.1007/s002340050404 · Cited by 121
Origin of subarachnoid cerebrospinal fluid pulsations: a phase-contrast MR analysis
Henry–Feugeas, M.-C., Idy-Peretti, I., Balédent, O., Poncelet–Didon, A., Zannoli, G., Bittoun, J., & Schouman‐Claeys, E. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00142-3 · Cited by 118
Temporal and spatial assessment of normal cerebrospinal fluid dynamics with MR imaging
Henry–Feugeas, M.-C., Idy-Peretti, I., Blanchet, B., Hassine, D., Zannoli, G., & Schouman‐Claeys, E. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90238-9 · Cited by 101
Epidural, Cerebrospinal Fluid, and Plasma Pharmacokinetics of Epidural Opioids (Part 2)
Bernards, C. M., Shen, D. D., Sterling, E. S., Adkins, J. E., Risler, L. J., Phillips, B., & Ummenhofer, W. C. (2003) · Anesthesiology · doi:10.1097/00000542-200308000-00030 · Cited by 65
Self-citation
Cited by
Deer, T. R., Pope, J. E., Hayek, S. M., Bux, A., Buchser, E., Eldabe, S., De Andrés, J. A., Erdek, M., Patin, D., Grider, J. S., et al. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12538 · Cited by 358
Deer, T. R., Prager, J., Levy, R., Rathmell, J., Buchser, E., Burton, A., Caraway, D., Cousins, M., De Andrés, J., Diwan, S., et al. (2012) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2012.00476.x · Cited by 327
Intrathecal Therapy for Cancer and Non-Cancer Pain
Hayek, S. M. (2011) · Pain Physician · doi:10.36076/ppj.2011/14/219 · Cited by 182
Robust spinal motor neuron transduction following intrathecal delivery of AAV9 in pigs
Federici, T., Taub, J. S., Baum, G. R., Gray, S. J., Grieger, J. C., Matthews, K. A., Handy, C. R., Passini, M. A., Samulski, R. J., & Boulis, N. M. (2012) · Gene Therapy · doi:10.1038/gt.2011.130 · Cited by 168
McDowell II, G. C., & Pope, J. E. (2016) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12392 · Cited by 57
“Patterns of drug distribution in the CSF that are influenced by these factors may be expected to have clinical implications for the efficacy and safety of IT medications (24,25).”
BackgroundDuarte, R. V., Raphael, J. H., Southall, J. L., Labib, M. H., Whallett, A. J., & Ashford, R. L. (2013) · BMJ Open · doi:10.1136/bmjopen-2013-002856 · Cited by 55
“The drug is highly localised, so its analgesic efficacy is maximised at lower doses.(4) Moreover, opioid dose escalation over the years may be modest.”
Background
Metadata
- Authors
- Bernards, C. M.
- Venue
- Anesthesiology
- Published
- 2006-07-01
- Volume
- 105
- Issue
- 1
- Pages
- 169-178
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2047765269
- Cited by
- 175
- References
- 9
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.