Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 268

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Airway Injuries after One-lung Ventilation: A Comparison between Double-lumen Tube and Endobronchial Blocker: A Randomized, Prospective, Controlled Trial

Knoll, Heike, Ziegeler, Stephan, Schreiber, Jan-Uwe, Buchinger, Heiko, Bialas, Patric, Semyonov, Kirill, Graeter, Thomas, Mencke, Thomas · 2006 · Anesthesiology

Abstract

Background: Vocal cord injuries, postoperative hoarseness, and sore throat are common complications after general anesthesia. One-lung ventilation can be achieved via two techniques: double-lumen endotracheal tube or endobronchial blocker such as the Arndt blocker. The current study was designed to assess the impact of these techniques for one-lung ventilation on the incidence and severity of postoperative hoarseness, vocal cord lesions, and sore throat. Methods: In this prospective trial, 60 patients were randomly assigned to two groups. One-lung ventilation was achieved with either an endobronchial blocker (blocker group) or a double-lumen-tube (double-lumen group). Postoperative hoarseness and sore throat were assessed at 24, 48, and 72 h after surgery. Bronchial injuries and vocal cord lesions were examined by bronchoscopy immediately after surgery. Results: In 56 included patients, postoperative hoarseness occurred significantly more frequently in the double-lumen group compared with the blocker group: 44% versus 17%, respectively (P = 0.046). Similar findings were observed for vocal cord lesions: 44% versus 17%, respectively (P = 0.046). The incidence of bronchial injuries was comparable between groups (P = 0.540). Cumulative number of days with hoarseness and sore throat were significantly increased in the double-lumen group compared with the blocker group (P < 0.01). No major complications such as bronchial ruptures were observed. Conclusions: Clinicians should be aware of an increased incidence of minor airway injuries that may impair patient satisfaction when using a double-lumen tube instead of an endobronchial blocker for one-lung ventilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200609000-00009

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 268

Metadata

Authors
Knoll, H., Ziegeler, S., Schreiber, J.-U., Buchinger, H., Bialas, P., Semyonov, K., Graeter, T., & Mencke, T.
Venue
Anesthesiology
Published
2006-09-01
Volume
105
Issue
3
Pages
471-477
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2114424498
Cited by
268
References
8
FWCI
6.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Airway Injuries after One-lung Ventilation: A Comparison between Double-lumen Tube and Endobronchial Blocker: A Randomized, Prospective, Controlled Trial. https://app.cochat.ai/papers/10.1097/00000542-200609000-00009
The paper
Knoll, H., Ziegeler, S., Schreiber, J.-U., Buchinger, H., Bialas, P., Semyonov, K., Graeter, T., & Mencke, T. (2006). Airway Injuries after One-lung Ventilation: A Comparison between Double-lumen Tube and Endobronchial Blocker: A Randomized, Prospective, Controlled Trial. Anesthesiology. https://doi.org/10.1097/00000542-200609000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.