Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 185

The DOI matches its Crossref record.

Telerobotic Laparoscopic Cholecystectomy: Initial Clinical Experience With 25 Patients

Open access
Marescaux, Jacques, Smith, Michelle K., Fölscher, Daniel, Jamali, Faek, Malassagne, Benoit, Leroy, Joel·2001·Annals of Surgery

Abstract

OBJECTIVE: To determine the safety and feasibility of performing telerobotic laparoscopic cholecystectomies. This will serve as a preliminary step toward the integration of computer-rendered three-dimensional preoperative imaging studies of anatomy and pathology onto the patient's own anatomy during surgery. SUMMARY BACKGROUND DATA: Computer-assisted surgery (CAS) increases the surgeon's dexterity and precision during minimally invasive surgery, especially when using microinstruments. Clinical trials have shown the improved microsurgical precision afforded by CAS in the minimally invasive setting in cardiac and gynecologic surgery. Future applications would allow integration of preoperative data and augmented-reality simulation onto the actual procedure. METHODS: Beginning in September 1999, CAS was used to perform cholecystectomies on 25 patients at a single medical center in this nonrandomized, prospective study. The operations were performed by one of two surgeons who had previous laboratory experience using the computer interface. The entire dissection was performed by the surgeon, who remained at a distance from the patient but in the same operating room. The operation was evaluated according to time of dissection, time of assembly/disassembly of robot, complications, immediate postoperative course, and short-term follow-up. RESULTS: Twenty of the 25 patients had symptomatic cholelithiasis, 1 had a gallbladder polyp, and 4 had acute cholecystitis. Twenty-four of the 25 laparoscopic cholecystectomies were successfully completed by CAS. There was one conversion to conventional laparoscopic cholecystectomy. Set-up and takedown of the robotic arms took a median of 18 minutes. The median operative time for dissection and the overall operative time were 25 and 108 minutes, respectively. There were no intraoperative complications. There was one postoperative complication of a suspected pulmonary embolus, which was treated with anticoagulation. All patients were tolerating diet at discharge. CONCLUSIONS: Laparoscopic cholecystectomy performed by CAS is safe and feasible, with operative times and patient recovery similar to those of conventional laparoscopy. At present, CAS cholecystectomy offers no obvious advantages to patients, but the potential advantages of CAS lie in its ability to convert the surgical act into digitized data. This digitized format can then interface with other forms of digitized data, such as pre- or intraoperative imaging studies, or be transmitted over a distance. This has the potential to revolutionize the way surgery is performed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000658-200107000-00001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Marescaux, J., Smith, M. K., Fölscher, D., Jamali, F., Malassagne, B., & Leroy, J.
Venue
Annals of Surgery
Published
2001-07
Volume
234
Issue
1
Pages
1-7
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2054855072
Cited by
185
References
0
FWCI
22.05
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Telerobotic Laparoscopic Cholecystectomy: Initial Clinical Experience With 25 Patients. https://app.cochat.ai/papers/10.1097/00000658-200107000-00001
The paper
Marescaux, J., Smith, M. K., Fölscher, D., Jamali, F., Malassagne, B., & Leroy, J. (2001). Telerobotic Laparoscopic Cholecystectomy: Initial Clinical Experience With 25 Patients. Annals of Surgery. https://doi.org/10.1097/00000658-200107000-00001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.