Robotic Surgical Training in an Academic Institution
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To detail robotic procedure development and clinical applications for mitral valve, biliary, and gastric reflux operations, and to implement a multispecialty robotic surgery training curriculum for both surgeons and surgical teams. SUMMARY BACKGROUND DATA: Remote, accurate telemanipulation of intracavitary instruments by general and cardiac surgeons is now possible. Complex technologic advancements in surgical robotics require well-designed training programs. Moreover, efficient robotic surgical procedures must be developed methodically and safely implemented clinically. METHODS: Advanced training on robotic systems provides surgeon confidence when operating in tiny intracavitary spaces. Three-dimensional vision and articulated instrument control are essential. The authors' two da Vinci robotic systems have been dedicated to procedure development, clinical surgery, and training of surgical specialists. Their center has been the first United States site to train surgeons formally in clinical robotics. RESULTS: Established surgeons and residents have been trained using a defined robotic surgical educational curriculum. Also, 30 multispecialty teams have been trained in robotic mechanics and electronics. Initially, robotic procedures were developed experimentally and are described. In the past year the authors have performed 52 robotic-assisted clinical operations: 18 mitral valve repairs, 20 cholecystectomies, and 14 Nissen fundoplications. These respective operations required 108, 28, and 73 minutes of robotic telemanipulation to complete. Procedure times for the last half of the abdominal operations decreased significantly, as did the knot-tying time in mitral operations. There have been no deaths and few complications. One mitral patient had postoperative bleeding. CONCLUSION: Robotic surgery can be performed safely with excellent results. The authors have developed an effective curriculum for training teams in robotic surgery. After training, surgeons have applied these methods effectively and safely.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Minimally Invasive and Robotic Surgery
Mack, M. J. (2001) · JAMA · doi:10.1001/jama.285.5.568 · Cited by 545
Telesurgical laparoscopic cholecystectomy
Himpens, J., Leman, G., & Cadiere, G. B. (1998) · Surgical Endoscopy · doi:10.1007/s004649900788 · Cited by 304
Video-Assisted and Robotic Mitral Valve Surgery: Toward an Endoscopic Surgery
Chitwood, W. R. (1999) · Seminars in Thoracic and Cardiovascular Surgery · doi:10.1016/s1043-0679(99)70060-2 · Cited by 210 · cited 2×
“The springboard for robotic mitral valve repair development was the endoscopic procedure spawned earlier at ECU.7,9,10 Ovine hearts best emulate human mitral valve size and configuration.”
MethodSelf-citationSimulation and Virtual Reality in Surgical Education: Real or Unreal?
Gorman, P. J., Meier, A. H., & Krummel, T. M. (1999) · Archives of Surgery · doi:10.1001/archsurg.134.11.1203 · Cited by 162
Early Experience with Telemanipulative Robot-Assisted Laparoscopic Cholecystectomy Using da Vinci
Kim, V. B., Chapman, W. H. H., Albrecht, R. J., Bailey, B. M., Young, J. A., Nifong, L. W., & Chitwood, W. R. (2002) · Surgical Laparoscopy Endoscopy & Percutaneous Techniques · doi:10.1097/00129689-200202000-00006 · Cited by 144
Self-citationVirtual Reality: Surgical Application— Challenge for The New Millennium
Meier, A. H., Rawn, C. L., & Krummel, T. M. (2001) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(01)00769-4 · Cited by 109
Computer-Assisted Training and Learning in Surgery
Gorman, P. J., Meier, A. H., & Krummel, T. M. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:2 · Cited by 65
Robotic-Assisted Adrenalectomy for Adrenal Incidentaloma: Case and Review of the Technique
Young, J. A., Chapman, W. H. H., Kim, V. B., Albrecht, R. J., Ng, P., Nifong, L. W., & Chitwood, W. R. (2002) · Surgical Laparoscopy Endoscopy & Percutaneous Techniques · doi:10.1097/00129689-200204000-00012 · Cited by 62
Self-citation
Cited by
A consensus document on robotic surgery
The SAGES-MIRA Robotic Surgery Consensus Group, Herron, D. M., & Marohn, M. (2008) · Surgical Endoscopy · doi:10.1007/s00464-007-9727-5 · Cited by 421
Training and learning robotic surgery, time for a more structured approach: a systematic review
Schreuder, H., Wolswijk, R., Zweemer, R., Schijven, M., & Verheijen, R. (2012) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2011.03139.x · Cited by 227
Breitenstein, S., Nocito, A., Puhan, M., Held, U., Weber, M., & Clavien, P.-A. (2008) · Annals of Surgery · doi:10.1097/sla.0b013e318172501f · Cited by 195
Randomized clinical trial of robot-assisted versus laparoscopic Nissen fundoplication
Morino, M., Pellegrino, L., Giaccone, C., Garrone, C., & Rebecchi, F. (2006) · British Journal of Surgery · doi:10.1002/bjs.5325 · Cited by 170
Da Vinci Xi robot-assisted penetrating keratoplasty
Chammas, J., Sauer, A., Pizzuto, J., Pouthier, F., Gaucher, D., Marescaux, J., Mutter, D., & Bourcier, T. (2017) · Translational Vision Science & Technology · doi:10.1167/tvst.6.3.21 · Cited by 52
Metadata
- Authors
- Chitwood, W. R., Nifong, L. W., Chapman, W. H. H., Felger, J. E., Bailey, B. M., Ballint, T., Mendleson, K. G., Kim, V. B., Young, J. A., & Albrecht, R. A.
- Venue
- Annals of Surgery
- Published
- 2001-10
- Volume
- 234
- Issue
- 4
- Pages
- 475-486
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2028377616
- Cited by
- 227
- References
- 8
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.