Bias in Studies of Preterm and Postterm Delivery Due to Ultrasound Assessment of Gestational Age
The DOI matches its Crossref record.
Abstract
Ultrasound measurement of fetal dimensions is widely used for estimating gestational age. A little-discussed limitation of this method is that variations in fetal size at a given stage of pregnancy are converted to differences in gestational age. Factors that affect pregnancy duration often affect fetal size also. We explore how the effect of such factors may be biased when gestational age is determined by ultrasound. We selected 3,606 women with singleton pregnancies (1989-1991) who had an early ultrasound measurement of fetal biparietal diameter (BPD) and a good-quality history of last menstrual period (LMP). Using the two measures of gestational age, we estimated risk of preterm and postterm delivery for female babies vs males and for smoking women vs nonsmoking women. There was a 13% excess of preterm delivery among female babies when gestational age was determined by ultrasound, but no excess when gestational age was defined by LMP. For postterm delivery, female babies had a 19% lower risk with ultrasound-defined age, but no deficit with LMP-defined age. We found a similar bias with ultrasound in the analysis of maternal smoking. Thus, factors that reduce fetal size inflate the risk of preterm delivery and deflate the risk of postterm delivery when gestational age is based on ultrasound measurement of the fetus. This bias can distort the relative risk of preterm or postterm delivery by 10-20%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quinn, J.-A., Munoz, F. M., Gonik, B., Frau, L., Cutland, C., Mallett-Moore, T., Kissou, A., Wittke, F., Das, M., Nunes, T., et al. (2016) · Vaccine · doi:10.1016/j.vaccine.2016.03.045 · Cited by 497
Shah, N. R., & Bracken, M. B. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(00)70240-7 · Cited by 394
Restricted fetal growth in sudden intrauterine unexplained death
Frøen, J. F., Gardosi, J. O., Thurmann, A., Francis, A., & Stray-Pedersen, B. (2004) · Acta Obstetricia et Gynecologica Scandinavica · doi:10.1080/j.0001-6349.2004.00602.x · Cited by 345
United States Birth Weight Reference Corrected For Implausible Gestational Age Estimates
Talge, N. M., Mudd, L. M., Sikorskii, A., & Basso, O. (2014) · Pediatrics · doi:10.1542/peds.2013-3285 · Cited by 338
Olesen, A. W., Westergaard, J. G., & Olsen, J. (2003) · American Journal of Obstetrics and Gynecology · doi:10.1067/mob.2003.446 · Cited by 278
Metadata
- Authors
- Henrihsen, T. B., Wilcox, A. J., Hedegaard, M., & Jørgen Secher, N.
- Venue
- Epidemiology
- Published
- 1995-09
- Volume
- 6
- Issue
- 5
- Pages
- 533-537
- ISSN
- 1044-3983 (ISSN-L)
- OpenAlex
- W2043744509
- Cited by
- 123
- References
- 0
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bias in Studies of Preterm and Postterm Delivery Due to Ultrasound Assessment of Gestational Age. https://app.cochat.ai/papers/10.1097/00001648-199509000-00012
- The paper
- Henrihsen, T. B., Wilcox, A. J., Hedegaard, M., & Jørgen Secher, N. (1995). Bias in Studies of Preterm and Postterm Delivery Due to Ultrasound Assessment of Gestational Age. Epidemiology. https://doi.org/10.1097/00001648-199509000-00012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.