Degradation Characteristics of PLLA-PGA Bone Fixation Devices
The DOI matches its Crossref record.
Abstract
Parietal craniotomies of the mature rabbit skull were repositioned and fixed with resorbable plate and screws made of LactoSorb (Walter Lorenz Surgical, Jacksonville, FL) poly L-lactic acid (PLLA) and polyglycolic acid (PGA) in 20 mature rabbits. Changes in the resorbable devices as well as at the tissue-implant interface were evaluated at 2, 6, 9, and 12 months postoperatively. At 2 months, no change in the size of the implants was seen with a noninflammatory layer of surrounding fibrous tissue and intense birefringence of the screws. At 6 months, substantial loss of implant size had occurred, accompanied by fibrovascular and a macrophage cellular infiltrate. At 9 months, more than 95% of the implant was resorbed, with a small amount remaining in the screw hole. Other than macrophages within the remaining material, very few giant cells were seen. By 1 year, no evidence of birefringent macromolecular polymer debris could be found. No contraindications for the clinical use of this specific PLLA-PGA copolyer could be found when implanted on craniofacial bone surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Biodegradable Materials for Bone Repairs: A Review
Tan, L., Yu, X., Wan, P., & Yang, K. (2013) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2013.03.002 · Cited by 431
Resorbable Plate Fixation in Pediatric Craniofacial Surgery: Long-term Outcome
Imola, M. J., Hamlar, D. D., Shao, W., Chowdhury, K., & Tatum, S. (2001) · Archives of Facial Plastic Surgery · doi:10.1001/archfaci.3.2.79 · Cited by 163
“The most extensive experience has been for interfragmentary fixation during cranial vault remodeling and fronto-orbital advancement in infants and young children with congenital craniofacial anomalies.(22-24) More recently the indications have expanded to include bone graft fixation, upper and midfacial fractures, as…”
The nanofibrous architecture of poly(l-lactic acid)-based functional copolymers
Liu, X., & Ma, P. X. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.046 · Cited by 104
The Use of High-Density Porous Polyethylene as a Custom-Made Nasal Spreader Graft
Gürlek, A., Celik, M., Fariz, A., Ersöz-Öztürk, A., Eren, A. T., & Tenekeci, G. (2006) · Aesthetic Plastic Surgery · doi:10.1007/s00266-005-0119-8 · Cited by 47
Metadata
- Authors
- Eppley, B. L., & Reilly, M.
- Venue
- Journal of Craniofacial Surgery
- Published
- 1997-03
- Volume
- 8
- Issue
- 2
- Pages
- 116-120
- ISSN
- 1049-2275 (ISSN-L)
- OpenAlex
- W1964901939
- Cited by
- 156
- References
- 0
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Degradation Characteristics of PLLA-PGA Bone Fixation Devices. https://app.cochat.ai/papers/10.1097/00001665-199703000-00010
- The paper
- Eppley, B. L., & Reilly, M. (1997). Degradation Characteristics of PLLA-PGA Bone Fixation Devices. Journal of Craniofacial Surgery. https://doi.org/10.1097/00001665-199703000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.