A New Method of 3-D Cephalometry Part I: The Anatomic Cartesian 3-D Reference System
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The purpose of this study was to present a new innovative three-dimensional (3-D) cephalometric method. Part I deals with the set-up and validation of a voxel-based semi-automatic 3-D cephalometric reference system. The CT data (DICOM 3.0 files) of 20 control patients with normal skeletal relationships were used for this study. To investigate accuracy and reliability of the 3-D cephalometric reference system (Maxilimtrade mark, version 1.3.0) a total of 42 (14 horizontal, 14 vertical and 14 transversal) orthogonal measurements were performed on each patient twice by each of two investigators. The intra-observer measurement error was less then 0.88 mm, 0.76 mm and 0.84 mm for horizontal, vertical and transversal orthogonal measurements, respectively. The inter-observer measurement error was less as 0.78 mm, 0.86 mm and 1.26 mm for horizontal, vertical and transversal orthogonal measurements, respectively. Squared correlation coefficients showed a high intra-observer and inter-observer reliability. The presented 3-D cephalometric reference system proved to be accurate and reliable and can therefore be used for 3-D cephalometric hard and soft tissue analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A NEW X-RAY TECHNIQUE and ITS APPLICATION TO ORTHODONTIA
Broadbent, B. H. (2009) · The Angle Orthodontist · doi:10.1043/0003-3219(1931)001<0045:anxtai>2.0.co;2 · Cited by 1,063
The three-dimensional cephalogram: Theory, techniques, and clinical application
Grayson, B. H., Cutting, C. B., Bookstein, F. L., Kim, H., & McCarthy, J. G. (1988) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/0889-5406(88)90058-3 · Cited by 149
Three‐dimensional assessment of treatment outcomes on the face
Moss, J. P., ISMAIL, S. F., & Hennessy, R. J. (2003) · Orthodontics and Craniofacial Research · doi:10.1034/j.1600-0544.2003.245.x · Cited by 59
Enciso, R., Memon, A., & Mah, J. (2003) · Orthodontics and Craniofacial Research · doi:10.1034/j.1600-0544.2003.237.x · Cited by 58
Craniofacial computed tomography scanning: technology, applications and future trends
Vannier, M. W. (2003) · Orthodontics and Craniofacial Research · doi:10.1034/j.1600-0544.2003.232.x · Cited by 56
A simulator for maxillofacial surgery integrating 3D cephalometry and orthodontia
Bettega, G., Payan, Y., Mollard, B., Boyer, A., Raphaël, B., & Lavall�e, S. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:3<156::aid-igs3>3.0.co;2-6 · Cited by 50
On the Assets of CAD Planning for Craniosynostosis Surgery
Mommaerts, M. Y., Jans, G., Sloten, J. V., Staels, P. F. J., der Perre, G. V., & Gobin, R. (2001) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200111000-00008 · Cited by 44
Swennen, G. R. J., Grimaldi, H., Berten, J.-L., Kramer, F., Dempf, R., Schwestka‐Polly, R., & Hausamen, J.-E. (2004) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200405000-00010 · Cited by 28 · cited 4×
“The inter-observer error was quantified as the standard deviation of the mean of differences between the averages of the paired duplicate data (x = x1 + x2)/2; y = y1 + y2) /2) measured by each investigator on the same variable according to Bland and Altman.(3,4,32) Fig 6 The 3-D anterior cranial base (S-N) plane is a…”
MethodInfluentialSelf-citation
Cited by
Hsu, S. S.-P., Gateno, J., Bell, R. B., Hirsch, D. L., Markiewicz, M. R., Teichgraeber, J. F., Zhou, X., & Xia, J. J. (2013) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2012.03.027 · Cited by 435
Plooij, J. M., Maal, T. J. J., Haers, P., Borstlap, W. A., Kuijpers-Jagtman, A. M., & Bergé, S. J. (2011) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2010.10.013 · Cited by 309
Plooij, J. M., Swennen, G. R. J., Rangel, F. A., Maal, T. J. J., Schutyser, F. A. C., Bronkhorst, E. M., Kuijpers–Jagtman, A. M., & Bergé, S. J. (2009) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2008.12.009 · Cited by 229
Self-citationde Oliveira, A. E. F., Cevidanes, L. H. S., Phillips, C., Motta, A., Burke, B., & Tyndall, D. (2009) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2008.05.039 · Cited by 209
Anatomic measures of upper airway structures in obstructive sleep apnea
Barrera, J. E., Pau, C. Y., Forest, V., Holbrook, A. B., & Popelka, G. R. (2017) · World Journal of Otorhinolaryngology - Head and Neck Surgery · doi:10.1016/j.wjorl.2017.05.002 · Cited by 75
Metadata
- Authors
- Swennen, G. R. J., Schutyser, F., Barth, E.-L., De Groeve, P., & De Mey, A.
- Venue
- Journal of Craniofacial Surgery
- Published
- 2006-03
- Volume
- 17
- Issue
- 2
- Pages
- 314-325
- ISSN
- 1049-2275 (ISSN-L)
- OpenAlex
- W1975315262
- Cited by
- 193
- References
- 9
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.