Stability of coagulation proteins in frozen plasma
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study reports on the frozen stability of all commonly measured coagulation proteins in normal citrated plasma: activated partial thromboplastin time, prothrombin time (%), thrombin time and fibrinogen (Clauss); clotting assays for factors II, V, VII, VIII, IX, X, XI and XII; functional assays for protein C (clotting), protein S (clotting), antithrombin (chromogenic) and plasminogen (chromogenic); and immunological assays for von Willebrand factor and D-dimer. All these factors listed are stable for up to 3 months if frozen at -24 degrees C or lower. At -74 degrees C, all these factors (allowing for 10% variation) were stable for at least 18 months, most were stable for 24 months. The number of proteins showing > 5% variation over baseline after 6 months storage indicates that some decay does occur even at -74 degrees C. There was no clear advantage in snap freezing at -74 degrees C and then storing at -24 degrees C over both freezing and storing at -24 degrees C; therefore, the freezing process itself is not responsible for the loss of stability. The best stability, especially at -24 degrees C, was obtained when small samples (1 ml) were stored in screw-cap tubes with a minimum dead space. The decrease in stability of the coagulation proteins directly correlates with the effect of temperature and time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of Fibrinogen in Frozen Plasma
McNerlan, S., Crawford, V. L. S., & Stout, R. W. (1997) · Thrombosis Research · doi:10.1016/s0049-3848(97)00283-1 · Cited by 14
Cited by
Guidelines for the management of hemophilia
Srivastava, A., Brewer, A. K., Mauser‐Bunschoten, E. P., Key, N. S., Kitchen, S., Llinas, A., Ludlam, C. A., Mahlangu, J. N., Mulder, K., Poon, M. C., et al. (2013) · Haemophilia · doi:10.1111/j.1365-2516.2012.02909.x · Cited by 1,927
Bolton‐Maggs, P. H. B., Perry, D. J., Chalmers, E. A., Parapia, L. A., Wilde, J. T., Williams, M. D., Collins, P. W., Kitchen, S., Dolan, G., & Mumford, A. D. (2004) · Haemophilia · doi:10.1111/j.1365-2516.2004.00944.x · Cited by 546
D-Dimer Concentrations in Normal Pregnancy: New Diagnostic Thresholds Are Needed
Kline, J. A., Williams, G. W., & Hernandez-Nino, J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.044883 · Cited by 251
Wolf, K., Tsakiris, D. A., Weber, R., Erb, P., Battegay, M., & Study, S. H. C. (2002) · The Journal of Infectious Diseases · doi:10.1086/338572 · Cited by 234
“Recently published data about the stability of the parameters we tested indicate that coagulation proteins remain stable for at least 18–24 months when stored in frozen plasma at 274 C [27].”
BackgroundD-dimer: Preanalytical, analytical, postanalytical variables, and clinical applications
Favresse, J., Lippi, G., Roy, P.-M., Chatelain, B., Jacqmin, H., ten Cate, H., & Mullier, F. (2018) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1529734 · Cited by 212
Metadata
- Authors
- Woodhams, B., Girardot, O., Blanco, M. J., Colesse, G., & Gourmelin, Y.
- Venue
- Blood Coagulation and Fibrinolysis
- Published
- 2001-06
- Volume
- 12
- Issue
- 4
- Pages
- 229-236
- ISSN
- 0957-5235 (ISSN-L)
- OpenAlex
- W2056953534
- Cited by
- 187
- References
- 1
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.