The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Endplate Potentials Are Common to Midfiber Myofacial Trigger Points
Abstract
OBJECTIVES: To compare the prevalence of motor endplate potentials (noise and spikes) in active central myofascial trigger points, endplate zones, and taut bands of skeletal muscle to assess the specificity of endplate potentials to myofascial trigger points. DESIGN: This nonrandomized, unblinded needle examination of myofascial trigger points compares the prevalence of three forms of endplate potentials at one test site and two control sites in 11 muscles of 10 subjects. The endplate zone was independently determined electrically. Active central myofascial trigger points were identified by spot tenderness in a palpable taut band of muscle, a local twitch response to snapping palpation, and the subject's recognition of pain elicited by pressure on the tender spot. RESULTS: Endplate noise without spikes occurred in all 11 muscles at trigger-point sites, in four muscles at endplate zone sites outside of trigger points (P = 0.024), and did not occur in taut band sites outside of an endplate zone (P = 0.000034). CONCLUSIONS: Endplate noise was significantly more prevalent in myofascial trigger points than in sites that were outside of a trigger point but still within the endplate zone. Endplate noise seems to be characteristic of, but is not restricted to, the region of a myofascial trigger point.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interrater reliability in myofascial trigger point examination
Gerwin, R. D., Shannon, S., Hong, C.-Z., Hubbard, D., & Gevirtz, R. (1997) · Pain · doi:10.1016/s0304-3959(96)03248-4 · Cited by 691
Self-citationAn investigation of spontaneous activity at the neuromuscular junction of the rat
Liley, A. W. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005555 · Cited by 568
Myofascial Trigger Points Show Spontaneous Needle EMG Activity
Hubbard, D. R., & Berkoff, G. M. (1993) · Spine · doi:10.1097/00007632-199310000-00015 · Cited by 549
Spontaneous electrical activity of human muscle
Buchthal, F., & Rosenfalck, P. (1966) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(66)90001-0 · Cited by 187
Simons, D., Hong, C., & Simons, L. S. (1995) · Journal of Musculoskeletal Pain · doi:10.1300/j094v03n01_04 · Cited by 147
Self-citationSigns and symptoms of the myofascial pain syndrome: a national survey of pain management providers.
Harden, R., Bruehl, S., Gass, S., Niemiec, C., & Barbick, B. (2000) · The Clinical Journal of Pain · doi:10.1097/00002508-200003000-00010 · Cited by 138
Do Endplate Noise and Spikes Arise from Normal Motor Endplates?
Simons, D. (2001) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200102000-00012 · Cited by 124
Self-citationMyofascial pain syndrome: electromyographic changes associated with local twitch response.
Fricton, J., Auvinen, M. D., Dykstra, D. D., & SCHIFFMAN, E. L. (1985) · PubMed · Cited by 108
Couppé, C., Midttun, A., Hilden, J., et al. (2001) · Journal of Musculoskeletal Pain · doi:10.1300/j094v09n03_02 · Cited by 107
“End‐plate noise” in electromyography
Wiederholt, W. (1970) · Neurology · doi:10.1212/wnl.20.3.214 · Cited by 93
Cited by
Review of enigmatic MTrPs as a common cause of enigmatic musculoskeletal pain and dysfunction
Simons, D. G. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2003.09.018 · Cited by 565
Self-citationAn expansion of Simons’ integrated hypothesis of trigger point formation
Gerwin, R. D., Dommerholt, J., & Shah, J. P. (2004) · Current Pain and Headache Reports · doi:10.1007/s11916-004-0069-x · Cited by 389
Borg-Stein, J., & Simons, D. G. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32155 · Cited by 317
Self-citationDry needling — peripheral and central considerations
Dommerholt, J. (2011) · Journal of Manual & Manipulative Therapy · doi:10.1179/106698111x13129729552065 · Cited by 315
Lucas, N., Macaskill, P., Irwig, L., Moran, R., & Bogduk, N. (2009) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e31817e13b6 · Cited by 295
Metadata
- Authors
- Simons, D. G., Hong, C.-Z., & Simons, L. S.
- Venue
- American Journal of Physical Medicine & Rehabilitation
- Published
- 2002-03
- Volume
- 81
- Issue
- 3
- Pages
- 212-222
- ISSN
- 0894-9115 (ISSN-L)
- OpenAlex
- W2086370253
- Cited by
- 302
- References
- 14
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Endplate Potentials Are Common to Midfiber Myofacial Trigger Points. https://app.cochat.ai/papers/10.1097/00002060-200203000-00010
- The paper
- Simons, D. G., Hong, C.-Z., & Simons, L. S. (2002). Endplate Potentials Are Common to Midfiber Myofacial Trigger Points. American Journal of Physical Medicine & Rehabilitation. https://doi.org/10.1097/00002060-200203000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.