CoChat

Reproducibility Indices Applied to Cervical Pressure Pain Threshold Measurements in Healthy Subjects

Prushansky, Tamara, Dvir, Zeevi, Defrin-Assa, Ruth · 2004 · The Clinical Journal of Pain
Cited by 103

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To apply various statistical indices for reproducibility analysis of pressure pain threshold measurements and to derive a preferred pressure pain threshold measurement protocol based on these indices. METHODS: The pressure pain threshold of 3 pairs of right and left homologous cervical region sites were measured in 20 healthy subjects (10 women, 10 men) using a hand-held pressure algometer. Measurements took place on 2 occasions (test 1 and test 2) separated by a mean interval of 1 week. On each testing session, the site-related pressure pain thresholds were measured 3 times each according to 2 different protocols. Protocol A consisted of a repetitive order, namely 3 consecutive measurements at each site before proceeding to the next, whereas protocol B consisted of an alternate order in which 3 consecutive rounds of all individually tested sites took place. For test 1, protocol A was followed by protocol B with an hour interval. For test 2, the reverse order took place. RESULTS: The findings revealed no significant differences between the two protocols and indicated a significant rise (P < 0.0001) in the absolute scores from test 1 to test 2 in both protocols. Absolute values (mean +/-SD) derived from the entire sample of pressure pain threshold sites ranged from 140 +/- 60 to 198.7 +/- 95 kPa (1.60 +/- 0.6 to 1.99 +/- 0.95 kg/cm, respectively). No significant gender or side differences were noted. Pearson r as well as the intraclass correlation coefficient revealed good to excellent reproducibility for both protocols and for all sites measured: r = 0.79-0.94 and intraclass correlation coefficient(3,3) = 0.85-0.96, respectively. To define site-specific cutoff values indicating change at the 95% confidence level, 1.96*SEM was calculated, and its values ranged from 31.6 to 58.2 kPa, which correspond to 16.8% to 32.8% of the absolute mean values. In addition, the limits of agreement, which depict the individual test-retest differences relative to their mean, indicated a heteroscedastic trend. DISCUSSION: The two protocols yielded very similar results. However, on the grounds of patient's comfort and compliance as well as facility of application, protocol B stands out as the more preferred between the two.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00002508-200409000-00009

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 103

Metadata

Authors
Prushansky, T., Dvir, Z., & Defrin-Assa, R.
Venue
The Clinical Journal of Pain
Published
2004
Volume
20
Issue
5
Pages
341-347
ISSN
0749-8047 (ISSN-L)
OpenAlex
W2078948827
Cited by
103
References
1
FWCI
2.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility Indices Applied to Cervical Pressure Pain Threshold Measurements in Healthy Subjects. https://app.cochat.ai/papers/10.1097/00002508-200409000-00009
The paper
Prushansky, T., Dvir, Z., & Defrin-Assa, R. (2004). Reproducibility Indices Applied to Cervical Pressure Pain Threshold Measurements in Healthy Subjects. The Clinical Journal of Pain. https://doi.org/10.1097/00002508-200409000-00009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.