The Stabilizing System of the Spine. Part II. Neutral Zone and Instability Hypothesis
The DOI matches its Crossref record.
Abstract
The neutral zone is a region of intervertebral motion around the neutral posture where little resistance is offered by the passive spinal column. Several studies--in vitro cadaveric, in vivo animal, and mathematical simulations--have shown that the neutral zone is a parameter that correlates well with other parameters indicative of instability of the spinal system. It has been found to increase with injury, and possibly with degeneration, to decrease with muscle force increase across the spanned level, and also to decrease with instrumented spinal fixation. In most of these studies, the change in the neutral zone was found to be more sensitive than the change in the corresponding range of motion. The neutral zone appears to be a clinically important measure of spinal stability function. It may increase with injury to the spinal column or with weakness of the muscles, which in turn may result in spinal instability or a low-back problem. It may decrease, and may be brought within the physiological limits, by osteophyte formation, surgical fixation/fusion, and muscle strengthening. The spinal stabilizing system adjusts so that the neutral zone remains within certain physiological thresholds to avoid clinical instability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cited by
Items 1,001–1,003 of 1,003
Watt, A. A., Callaway, A. J., & Williams, J. M. (2022) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-022-02609-w · Cited by 5
Fewster, K. M., Gallagher, K. M., & Callaghan, J. P. (2024) · Journal of Applied Biomechanics · doi:10.1123/jab.2023-0039 · Cited by 5
Quantifying Muscle Fatigue of the Low Back during Repetitive Load Lifting Using Lyapunov Analysis
Spyropoulos, E., Kyvelidou, A., Stergiou, N., & Athanassiou, G. (2016) · Journal of Ergonomics · doi:10.4172/2165-7556.1000180 · Cited by 5
“, being pushed) perturbations [7] as well as and more commonly by the transition from the neuromuscular non-fatigued to the fatigue stage leading to a change of the spine movement trajectories.”
Background
Metadata
- Authors
- Panjabi, M. M.
- Affiliations
- Yale University (US)
- Corresponding author
- Panjabi, Manohar M.
- Venue
- Journal of Spinal Disorders
- Published
- 1992-12
- Volume
- 5
- Issue
- 4
- Pages
- 390-397
- ISSN
- 0895-0385 (ISSN-L)
- OpenAlex
- W1965812174
- Cited by
- 1,991
- References
- 0
- Citations by year
- 2026: 69 · 2025: 72 · 2024: 72 · 2023: 71 · 2022: 89 · 2021: 98 · 2020: 93 · 2019: 66 · 2018: 94 · 2017: 80 · 2016: 104 · 2015: 93 · 2014: 109 · 2013: 108 · 2012: 91
- FWCI
- 2.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Spinal Disorders (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R01AR039209, R01AR030361)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Spine and Intervertebral Disc Pathology
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Health Sciences › Medicine › Surgery › Scoliosis diagnosis and treatment
- Keywords
- spinal stability, neutral zone, spinal instability, intervertebral motion, low back pain, spinal injuries, degenerative spine disease, muscle strength, osteophytes, spinal fusion, range of motion
- MeSH terms
- Animals, Biomechanical Phenomena, Humans, Joint Instability, Models, Biological, Movement, Muscles, Posture, Spinal Diseases, Spine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.