The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner
Abstract
PURPOSE: To compare combined whole-body PET and CT images of different cancers with PET images alone. MATERIALS AND METHODS: Thirty-two patients with known or possible cancers were examined using a combined positron emission tomographic (PET) and computed tomographic (CT) scanner. All data were acquired using this same combined scanner. After an injection of F-18 fluorodeoxyglucose (FDG), noncontrast helical CT imaging of the neck, chest, abdomen, or pelvis was performed. The spiral CT was followed by a PET scan covering the same axial extent as the CT. RESULTS: Coregistered PET-CT images identified and localized 55 lesions. In 10 patients (31%), areas with variable amounts of normal physiologic FDG uptake were distinguished from potential uptake of FDG in a nearby neoplastic lesion. Improved localization was achieved in 9 patients (for a total of 13 lesions, or 24%). CONCLUSION: Combined PET-CT images appear more effective than PET images alone to localize precisely neoplastic lesions and to distinguish normal variants from juxtaposed neoplastic lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Self-citation
Cited by
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Self-citationClinical Role of FDG PET in Evaluation of Cancer Patients
Kostakoglu, L., Agress, H., & Goldsmith, S. J. (2003) · RadioGraphics · doi:10.1148/rg.232025705 · Cited by 402
Blodgett, T. M., Meltzer, C. C., & Townsend, D. W. (2007) · Radiology · doi:10.1148/radiol.2422051113 · Cited by 387
Self-citationMultimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
Self-citationPET/CT scanners: A hardware approach to image fusion
Townsend, D. W., Beyer, T., & Blodgett, T. M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127314 · Cited by 262
Self-citation
Metadata
- Authors
- CHARRON, M., BEYER, T., BOHNEN, N. N., KINAHAN, P. E., DACHILLE, M., JERIN, J., NUTT, R., MELTZER, C. C., VILLEMAGNE, V., & TOWNSEND, D. W.
- Venue
- Clinical Nuclear Medicine
- Published
- 2000-11
- Volume
- 25
- Issue
- 11
- Pages
- 905-910
- ISSN
- 0363-9762 (ISSN-L)
- OpenAlex
- W2330692775
- Cited by
- 170
- References
- 1
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner. https://app.cochat.ai/papers/10.1097/00003072-200011000-00010
- The paper
- CHARRON, M., BEYER, T., BOHNEN, N. N., KINAHAN, P. E., DACHILLE, M., JERIN, J., NUTT, R., MELTZER, C. C., VILLEMAGNE, V., & TOWNSEND, D. W. (2000). Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner. Clinical Nuclear Medicine. https://doi.org/10.1097/00003072-200011000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.