The DOI matches its Crossref record.
A Non-Operative Salvage of Surgically-Resistant Pseudarthroses and Non-Unions by Pulsing Electromagnetic Fields: A Preliminary Report
Abstract
This report documents, for the first time, to the authors' knowledge, the therapeutic use in humans of low energy, electromagnetic fields pulsing in the extremely low frequency (E.L.F.) range. These fields, established outside the body, were used to treat congenital and acquired pseudarthroses and non-unions. Energy of this type appears to affect biological processes, not through heat production, but through electrically-induced changes in the environment of cells within the organism. Of the 29 patients included in the study, 17 had experienced at least one failure of surgical repair and, in each of these, amputation had been recommended. The overall success rate, including those patients treated with inadequate pulse characteristics and those who failed to follow the protocol, was in excess of 70 per cent. Improvements in the specificity of pulse characteristics hold promise for increasing the rate of success. The simple, clinical methodology, which is conducted on an out-patient basis, appears to be both safe and effective. It can be applied with or without surgery. This approach requires additional controlled investigations before it is ready for general use in the orthopaedic community. The indications for amputation of surgically-resistant pseudarthroses, however, should be reassessed. The principles and technology, which have been established during this endeavor, may have physiologic and practical significance for processes other than pseudarthrosis and non-union.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Friedlaender, G. E., Perry, C. R., Cole, J. D., Cook, S. D., Cierny, G., Muschler, G. F., Zych, G. A., Calhoun, J. H., LaForte, A. J., & Yin, S. (2001) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200100002-00010 · Cited by 957
Pulsing Electromagnetic Field Treatment in Ununited Fractures and Failed Arthrodeses
Bassett, C. A. L. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03320300027017 · Cited by 282
Self-citationLuben, R. A., Cain, C. D., Chen, M. C.-Y., Rosen, D. M., & Adey, W. R. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.13.4180 · Cited by 280
Bassett, C. A. L. (1985) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)31696-5 · Cited by 60
Self-citation
Metadata
- Authors
- BASSETT, C. A. L., PILLA, A. A., & PAWLUK, R. J.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1977-05
- Volume
- 124
- Issue
- 124
- Pages
- 128-143
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1997004294
- Cited by
- 270
- References
- 0
- FWCI
- 9.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Non-Operative Salvage of Surgically-Resistant Pseudarthroses and Non-Unions by Pulsing Electromagnetic Fields: A Preliminary Report. https://app.cochat.ai/papers/10.1097/00003086-197705000-00017
- The paper
- BASSETT, C. A. L., PILLA, A. A., & PAWLUK, R. J. (1977). A Non-Operative Salvage of Surgically-Resistant Pseudarthroses and Non-Unions by Pulsing Electromagnetic Fields: A Preliminary Report. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-197705000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.