The DOI matches its Crossref record.
Experimental Mechanical and Histologic Evaluation of the Kennedy Ligament Augmentation Device
Abstract
Reconstruction of the knee with a chronic injury to the anterior cruciate ligament is an unsolved problem. Biologic graft substitutes have failed to maintain knee stability in the longer postreconstruction intervals. In an attempt to overcome the limitations in graft performance, synthetic materials have been proposed to augment the biologic tissue. In this study, a 6-mm polypropylene braid Ligament Augmentation Device (LAD) possessing a tensile strength of 1500 N and excellent fatigue and creep properties was investigated as an adjunct to the MacIntosh/Marshall Over-the-Top repair. A two-year animal study of 54 adult goats was conducted in which experimental ACL defects were created and reconstructed with a transplant consisting of a portion of the rectus femoris tendon, prepatellar tissue, and the central one-third of the patellar tendon. The goats were equally divided between nonaugmented and LAD-augmented groups and sacrificed at three, six, 12, and 24 months after surgery. Mechanically, the augmented transplants were substantially stronger at the time of initial implantation (364N versus 26N) and again at two years (841N versus 528N). Intermediate times did not demonstrate a difference in strength. Histologically, the augmented transplants consisted of a loosely organized fibrous capsule surrounding the LAD. At 24 months, "insertion fibers" were noted to provide continuity between the fibrous tissue and bone on both the tibia and femur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tissue Engineering: Orthopedic Applications
Laurencin, C. T., Ambrosio, A. M. A., Borden, M. D., & Cooper, J. A. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.19 · Cited by 752
Cooper, J. A., Lu, H. H., Ko, F. K., Freeman, J. W., & Laurencin, C. T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.014 · Cited by 481
Lu, H. H., Cooper, J. A., Manuel, S., Freeman, J. W., Attawia, M. A., Ko, F. K., & Laurencin, C. T. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.11.050 · Cited by 380
Snedeker, J. G., & Foolen, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.032 · Cited by 377
Tomita, F., Yasuda, K., Mikami, S., Sakai, T., Yamazaki, S., & Tohyama, H. (2001) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2001.24059 · Cited by 306
Metadata
- Authors
- MCPHERSON, G. K., MENDENHALL, H. V., GIBBONS, D. F., PLENK, H., ROTTMANN, W., SANFORD, J. B., KENNEDY, J. C., & ROTH, J. H.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1985-06
- Volume
- 196
- Issue
- 196
- Pages
- 186-195
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W4295993540
- Cited by
- 190
- References
- 0
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental Mechanical and Histologic Evaluation of the Kennedy Ligament Augmentation Device. https://app.cochat.ai/papers/10.1097/00003086-198506000-00025
- The paper
- MCPHERSON, G. K., MENDENHALL, H. V., GIBBONS, D. F., PLENK, H., ROTTMANN, W., SANFORD, J. B., KENNEDY, J. C., & ROTH, J. H. (1985). Experimental Mechanical and Histologic Evaluation of the Kennedy Ligament Augmentation Device. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198506000-00025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.